HP 4400 HP B-series Fabric OS 7.0.0a Release Notes (5697-0881, June 2011) - Page 46
The HP StorageWorks DC04 SAN Director Switch is experiencing
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
Closed fixes summary Solution Zone corruption occurs when copying all zonesets from one AD to another using "zone --copy ". Subsequent zoning related operations may result in zone termination and switch reboot. Workaround prior to upgrade:To avoid the corruption code flow, instead of copying all zonesets at once from one AD to another (using zone --copy ), copy zonesets one by one using zone --copy source_zoneset> Fixed in Fabric OS 7.0.0. Customers may experience a large number of CRC errors and reduced performance on data transfers when connecting to tape drives on an Fixed in Fabric OS 7.0.0. HP 8/40 SAN Switch with Finisar optics. No error message was output when an incorrect syntax was used for the "cryptocfg --create -container" command . Subsequently, the customer had difficulty in configuring the HP StorageWorks Encryption SAN Switch because the incorrect syntax in the CLI creation of a container caused a problem when trying to define LUNs. Fixed in Fabric OS 7.0.0. The help text in Fabric OS 6.3.0 does not reflect the trackchangesset command is deprecated. Even though the command can still be entered, it has no effect. Fixed in Fabric OS 7.0.0. The HP StorageWorks DC04 SAN Director Switch is experiencing a high rate of internal CRC errors on select links. Fixed in Fabric OS 7.0.0. For both IPv4 and IPv6, the ipfilter tool incorrectly leaves unfiltered TCP and UDP ports 1024-49151 (inclusive), as well as TCP ports 80 and 443. These ports may not be blocked implicitly or explicitly. Fixed in Fabric OS 7.0.0. In a FICON environment, customers may experience IFCCs from CUP due to Address specific bit NOT being set. Fixed in Fabric OS 7.0.0. In a FICON environment, an SNMP query of nodeRNIDPortType will indicate n-port for E_Ports. Fixed in Fabric OS 7.0.0. The HP 2408 FCoE Switch does not update the optics digital diagnostics data during runtime. The 'show media' command does not show the TX/RX power value correctly after the user disconnects and reconnects the optical cable. Fixed in Fabric OS 7.0.0. In Fabric OS 6.4.1b, the RMON alarm value for etherStatsOversizePkts is not updated and is permanently set to 0. Fixed in Fabric OS 7.0.0. Various configuration status are not reflected to configFile. When a policy is modified by a user and uploaded via configUpload, the res- Fixed in Fabric OS 7.0.0. ulting configFile does not reflect the updated policy. FICON MIB traps are missing .21 in their OID resulting in a mismatch between the FICON link incident MIB trap OID prefix sent from a switch with the actual OID values for these traps as per the MIB definition and MIB reference manual. Fixed in Fabric OS 7.0.0. Class three frame discards may occur when supportshow is executed. Customer may observe SCSI/IO errors when supportsave is executed on specific platforms such as the HP 8/8 SAN Switch, HP 8/24 SAN Switch, HP 8/80 SAN Switch. Fixed in Fabric OS 7.0.0. 46