HP 4400 HP B-series Fabric OS 7.0.0a Release Notes (5697-0881, June 2011) - Page 47

on an HP DC SAN Director 10/24 FCoE Blade even though these

Page 47 highlights

Closed fixes summary Solution The cfgclear description in CLI is misleading. The cfgsave command is required after executing the cfgclear command, but that is not clear Fixed in Fabric OS 7.0.0. from the description. The OUI 00:24:ff is not being translated in the WWN Company ID of the WebTools Name Server window and zoning window. Fixed in Fabric OS 7.0.0. Multiple paths went down on customers servers due to frames being periodically rejected by the switch. Fixed in Fabric OS 7.0.0. The port auto disable feature is not disabling all of the E_Ports on an HP StorageWorks DC SAN Backbone Director Switch when Loss of Synch occurs. Fixed in Fabric OS 7.0.0. WebTools can be launched from the Fabric Tree when using auto configured IPv6 address but should not be. Fixed in Fabric OS 7.0.0. On a switch with only IPv6 Address configured, users are unable to create Certificate Signing Request (CSR) files with seccertutil command. Fixed in Fabric OS 7.0.0. The portcfgshow command does not indicate NPIV capability for ports on an HP DC SAN Director 10/24 FCoE Blade even though these Fixed in Fabric OS 7.0.0. ports do support NPIV. In WebTools, customers could be misled by switch icons if both a HP 2408 FCoE Switch and an HP 8/40 SAN Switch are present in the same deployment. Fixed in Fabric OS 7.0.0. In an FCIP environment, executing the supportshow clears the ftrace buffers. Fixed in Fabric OS 7.0.0. The portname command behavior was changed in 6.3.x causing the open portname command to no longer work. Fixed in Fabric OS 7.0.0. WebTools does not display the IPv6 address of the switch management port. Fixed in Fabric OS 7.0.0. Customer may notice core files and RAS messages generated due to cald software verify errors. Fixed in Fabric OS 7.0.0. On an AG switch, a customer may see a type2 miss error for every FDISC ACC which is misleading because the FDISC ACC should not be counted as a type2 miss. In large fabric config and large zone database, cfgenable is taking a long time with FCIP links. Fixed in Fabric OS 7.0.0. Users can disable the NPIV function on FCoE port of an HP 2408 FCoE Switch. Fixed in Fabric OS 7.0.0. The status of fwfrucfg and trackchangesset are not overwritten by configDownload. If a customer updates a FRU config status or trackchangeset status, then uploads the config file, followed by a configdefault, the status will not be restored upon download of the config file. Fixed in Fabric OS 7.0.0. There is no implementation of dynamic checking for secondary metadata. Fixed in Fabric OS 7.0.0. HP B-series Fabric OS 7.0.0a Release Notes 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Solution
Closed fixes summary
Fixed in Fabric OS 7.0.0.
The cfgclear description in CLI is misleading. The cfgsave command
is required after executing the cfgclear command, but that is not clear
from the description.
Fixed in Fabric OS 7.0.0.
The OUI 00:24:ff is not being translated in the WWN Company ID
of the WebTools Name Server window and zoning window.
Fixed in Fabric OS 7.0.0.
Multiple paths went down on customers servers due to frames being
periodically rejected by the switch.
Fixed in Fabric OS 7.0.0.
The port auto disable feature is not disabling all of the E_Ports on an
HP StorageWorks DC SAN Backbone Director Switch when Loss of
Synch occurs.
Fixed in Fabric OS 7.0.0.
WebTools can be launched from the Fabric Tree when using auto
configured IPv6 address but should not be.
Fixed in Fabric OS 7.0.0.
On a switch with only IPv6 Address configured, users are unable to
create Certificate Signing Request (CSR) files with seccertutil command.
Fixed in Fabric OS 7.0.0.
The portcfgshow command does not indicate NPIV capability for ports
on an HP DC SAN Director 10/24 FCoE Blade even though these
ports do support NPIV.
Fixed in Fabric OS 7.0.0.
In WebTools, customers could be misled by switch icons if both a HP
2408 FCoE Switch and an HP 8/40 SAN Switch are present in the
same deployment.
Fixed in Fabric OS 7.0.0.
In an FCIP environment, executing the supportshow clears the ftrace
buffers.
Fixed in Fabric OS 7.0.0.
The portname command behavior was changed in 6.3.x causing the
open portname command to no longer work.
Fixed in Fabric OS 7.0.0.
WebTools does not display the IPv6 address of the switch management
port.
Fixed in Fabric OS 7.0.0.
Customer may notice core files and RAS messages generated due to
cald software verify errors.
Fixed in Fabric OS 7.0.0.
On an AG switch, a customer may see a type2 miss error for every
FDISC ACC which is misleading because the FDISC ACC should not
be counted as a type2 miss.
In large fabric config and large zone database, cfgenable is taking
a long time with FCIP links.
Fixed in Fabric OS 7.0.0.
Users can disable the NPIV function on FCoE port of an HP 2408 FCoE
Switch.
Fixed in Fabric OS 7.0.0.
The status of fwfrucfg and trackchangesset are not overwritten by
configDownload. If a customer updates a FRU config status or
trackchangeset status, then uploads the config file, followed by a
configdefault, the status will not be restored upon download of the
config file.
Fixed in Fabric OS 7.0.0.
There is no implementation of dynamic checking for secondary
metadata.
HP B-series Fabric OS 7.0.0a Release Notes
47