HP 4400 HP B-series Fabric OS 7.0.0a Release Notes (5697-0881, June 2011) - Page 48
IPv6 named Certificate Signing Request CSR files may not be FTP'd
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
Closed fixes summary Solution It is not possible to make Enhanced TI zones on an HP 2408 FCoE Switch. Fixed in Fabric OS 7.0.0. The Relay Host IP in fwmailcfg must be reconfigures after firmwaredownload. Fixed in Fabric OS 7.0.0. The speed value of 8 Gbps acquired in ifSpeed differs from the specification. Fixed in Fabric OS 7.0.0. The documentation for the fabricprincipal command needs to be updated to indicate the CLI with -p 0x02 "should not" be used rather than "cannot be used" because the command can be executed successfully. Fixed in Fabric OS 7.0.0. SNMP traps and related RASLOGs may not be generated as expected. For example, SNMP-1008 messages and traps stop while a port is Fixed in Fabric OS 7.0.0. bouncing every 20 minutes. FCIP based acceleration sending Link Busy response to unsolicited status frame is causing failures. Fixed in Fabric OS 7.0.0. IPv6 named Certificate Signing Request (CSR) files may not be FTP'd to some Windows based ftp servers because Windows servers do not accept the ":" character in the filename which is present in IPv6 CSR filenames. Fixed in Fabric OS 7.0.0. DCFM Real-Time and Historical graph on FCIP tunnels with multiple HP StorageWorks B-Series Multi-protocol Router Blades display only one tunnel. Fixed in Fabric OS 7.0.0. Processes started during telnet session do not end when session abruptly ends; the fwmailcfg binary continues to run on the switch taking up Fixed in Fabric OS 7.0.0. large amounts of CPU cycles. There are some documentation errors in the Message Reference Guide for Fabric OS6.4.1. Fixed in Fabric OS 7.0.0. The HP 1606 SAN Extension Switch generates spurious C2-1011 raslog errors when portloopbacktest is run. Fixed in Fabric OS 7.0.0. There is no support for Windows LDAP with IPv6. Fixed in Fabric OS 7.0.0. There is no support for SFP inserted/absent/faulty states to Fabric Watch FRU monitoring catagory. Fixed in Fabric OS 7.0.0. The compression settings displayed with the "ALL" option do not show the active compression mode. Fixed in Fabric OS 7.0.0. If Ethernet settings have been customer configured via ifmodset, they may be reset to default values after a firmware upgrade. Workaround prior to upgrade:Reset Ethernet port parameters using ifmodeset command. Fixed in Fabric OS 7.0.0. Resources are lost when a circuit is down for long periods of time. There are complete FCIP Circuit and Tunnel failures after buffer pool resources are depleted on an HP 1606 SAN Extension Switch and HP DC SAN Director Multiprotocol Extension Blade. The tunnel is able to recover after a reboot is performed. Fixed in Fabric OS 7.0.0. 48