HP 4400 HP B-series Fabric OS 7.0.0a Release Notes (5697-0881, June 2011) - Page 51
StorageWorks DC SAN Backbone Director Switch in a large edge
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
Closed fixes summary An IPSec enabled FCIP circuit may bounce after running a 200 ms delay and 1% packet loss for 4 days. In Access Gateway mode, in WT-Port Admin, hitting the save button multiple times in the Edit configuration window may cause the WebLinker to crash. Solution Fixed in Fabric OS 7.0.0. Workaround prior to upgrade:Be sure to select the save button only once. Fixed in Fabric OS 7.0.0. Running system verification multiple times could cause HP DC SAN Director 10/24 FCoE Blade to fault. Fixed in Fabric OS 7.0.0. The supportshowcfgshow in supportsave does not match the output from a supportshow. Fixed in Fabric OS 7.0.0. Multiple devices lose connectivity when route is not deleted from previous trunk master after disabling and enabling the trunk. Fixed in Fabric OS 7.0.0. The HP StorageWorks DC SAN Backbone Director Switch management port speed of 1000 Mbps is displayed on WebTools as 10 Mbps. Fixed in Fabric OS 7.0.0. In a FICON environment, after IPL many FICON CHPIDs come up in Invalid Attachment state.With DCFM actively polling the fabric and reboot of the core HP StorageWorks DC SAN Backbone Director Switch in a large edge fabric, HA may go out of sync. Fixed in Fabric OS 7.0.0. With DCFM actively polling the fabric and reboot of the core HP StorageWorks DC SAN Backbone Director Switch in a large edge fabric, HA may go out of sync. Fixed in Fabric OS 7.0.0. A standby CP may experiences a software "VERIFY" error causing the CPs to lose sync.Port Auto Disable does not allow user finer granularity control over the 5 possible events for LINK DOWN that currently trigger a port being held offline. Fixed in Fabric OS 7.0.0. Port Auto Disable does not allow user finer granularity control over the 5 possible events for LINK DOWN that currently trigger a port being held offline. Fixed in Fabric OS 7.0.0. There is no functionality for querying all the IP addresses associated with the management interface of a device (both IPv4 and IPv6) over SNMP. Fixed in Fabric OS 7.0.0. Hard port faults may occur without warning messages and devices may lose their connectivity on the HP StorageWorks 4/32B SAN Switch running Fabric OS 5.3.0. Fixed in Fabric OS 7.0.0. There is no provision for adding a user configurable refresh to WebTools to decrease in the polling cycle time. Fixed in Fabric OS 7.0.0. Resets are not correctly captured in the HP StorageWorks B-series Multi-protocol Router Blade. Fixed in Fabric OS 7.0.0. "Token freed on wrong logical port" RAS message seen when cfgsave was executed. The cfgsave command does not complete in a fabric containing 6K devices. Workaround prior to upgrade:Avoid enabling the default all access with more number of devices. Fixed in Fabric OS 7.0.0. HP B-series Fabric OS 7.0.0a Release Notes 51