HP Cisco MDS 9120 Cisco MDS 9200 Series Hardware Installation Guide (OL-16188- - Page 29

LEDs on the Interface Module

Page 29 highlights

Chapter 1 Product Overview Interface Modules LEDs on the Interface Module Table 1-2 describes the LEDs for the Cisco MDS 9200 Series interface module. Table 1-2 LEDs on the Cisco MDS 9200 Series Interface Module LED Status Description Status Green All diagnostics pass. The module is operational (normal initialization sequence). Orange One of the following occurs or occurred: • The module is booting or running diagnostics (normal initialization sequence). • The inlet air temperature of the system exceeded the maximum system operating temperature limit (a minor environmental warning). To ensure maximum product life, you should immediately correct the environmental temperature and restore the system to normal operation. Red One of the following occurred: • The diagnostic test failed. The module is not operational because a fault occurred during the initialization sequence. • The inlet air temperature of the system exceeded the safe operating temperature limits of the card (a major environmental warning). The card shut down to prevent permanent damage. System Green All chassis environmental monitors are reporting OK. Orange One of the following occurs or occurred: • The power supply failed or the power supply fan failed. • Incompatible power supplies are installed. • The redundant clock failed. Red The temperature of the supervisor module exceeded the major threshold. MGMT 10/100 Green Ethernet Link Off LED Link is up. No link. MGMT 10/100 Green Ethernet Off Activity LED Traffic is flowing through port. No link or no traffic. OL-16188-01 Cisco MDS 9200 Series Hardware Installation Guide 1-11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

1-11
Cisco MDS 9200 Series Hardware Installation Guide
OL-16188-01
Chapter 1
Product Overview
Interface Modules
LEDs on the Interface Module
Table 1-2
describes the LEDs for the Cisco MDS 9200 Series interface module.
Table 1-2
LEDs on the Cisco MDS 9200 Series Interface Module
LED
Status
Description
Status
Green
All diagnostics pass. The module is operational
(normal initialization sequence).
Orange
One of the following occurs or occurred:
The module is booting or running diagnostics
(normal initialization sequence).
The inlet air temperature of the system exceeded
the maximum system operating temperature limit
(a minor environmental warning). To ensure
maximum product life, you should immediately
correct the environmental temperature and
restore the system to normal operation.
Red
One of the following occurred:
The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
T
he inlet air temperature of the system exceeded
the safe operating temperature limits of the card
(a major environmental warning). The card shut
down to prevent permanent damage.
System
Green
All chassis environmental monitors are reporting OK.
Orange
One of the following occurs or occurred:
The power supply failed or the power supply fan
failed.
Incompatible power supplies are installed.
The redundant clock failed.
Red
The temperature of the supervisor module exceeded
the major threshold.
MGMT 10/100
Ethernet Link
LED
Green
Link is up.
Off
No link.
MGMT 10/100
Ethernet
Activity LED
Green
Traffic is flowing through port.
Off