HP Cisco Nexus 5000 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS R - Page 41

Symptom, Workaround, show boot, output as shown below - slow

Page 41 highlights

Caveats Send documentation comments to [email protected] • CSCsr49954 Symptom: The Recoverpoint Appliance with a QLogic HBA sends an 8 byte RFT_ID instead of the standard 32bytes, which causes FC4 features to be incorrectly registered with all features. Workaround: This issue is resolved. • CSCsr53531 Symptom: In IVR NAT environment, after active mode PortChannel flaps, some member of the PortChannel may not get programmed in the IVR table, so that related IVR traffic will get lost. Workaround: This issue is resolved. • CSCsr94621 Symptom: A Fiber Channel over IP (FCIP) trunk can go down if the maximum transmission unit (MTU in the path is less than the MTU of the MDS Gigabit Ethernet interface. Workaround: This issue is resolved. • CSCsr98144 Symptom: If a sync-loss is received for a nonexisting fabric, the xbar-manager transitions to a state from which it does not exit. Workaround: This issue is resolved. • CSCsu06940 Symptom: An Octeon core occurred. Workaround: This problem is resolved. • CSCsu31223 Symptom: A slow memory leak has been found as a part of the view of the interface table MIB with the SME interfaces. This eventually results in the SNMPD process resetting due to lack of memory. Workaround: This issue is resolved. • CSCsr02430 Symptom: After issuing the show boot command, there are duplicate image names listed in the switch output as shown below: switch# show boot sup-1 kickstart variable not set system variable = bootflash:/m9500-sf1ek9-mzg.3.4.1.bin;bootflash:/m9500-sf1ek9mzg.3.4.1.bin sup-2 kickstart variable not set system variable = bootflash:/m9500-sf1ek9-mzg.3.4.1.bin;bootflash:/m9500-sf1ek9mzg.3.4.1.bin No module boot variable set switch# This occurs if you issue the boot system command twice with the same image name as shown below: switch(config)# boot system bootflash:m9500-sf1ek9-mzg.3.4.1.bin switch(config)# boot system bootflash:m9500-sf1ek9-mzg.3.4.1.bin Workaround: This issue is resolved. • CSCsq64637 Symptom: All device aliases in Fabric Manager disappear when adding new device aliases. OL-14116-10 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2) 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

Send documentation comments to [email protected]
41
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2)
OL-14116-10
Caveats
CSCsr49954
Symptom
: The Recoverpoint Appliance with a QLogic HBA sends an 8 byte RFT_ID instead of the
standard 32bytes, which causes FC4 features to be incorrectly registered with all features.
Workaround
: This issue is resolved.
CSCsr53531
Symptom
: In IVR NAT environment, after active mode PortChannel flaps, some member of the
PortChannel may not get programmed in the IVR table, so that related IVR traffic will get lost.
Workaround
: This issue is resolved.
CSCsr94621
Symptom
: A Fiber Channel over IP (FCIP) trunk can go down if the maximum transmission unit
(MTU in the path is less than the MTU of the MDS Gigabit Ethernet interface.
Workaround
: This issue is resolved.
CSCsr98144
Symptom
: If a sync-loss is received for a nonexisting fabric, the xbar-manager transitions to a state
from which it does not exit.
Workaround
: This issue is resolved.
CSCsu06940
Symptom
: An Octeon core occurred.
Workaround
: This problem is resolved.
CSCsu31223
Symptom
: A slow memory leak has been found as a part of the view of the interface table MIB with
the SME interfaces. This eventually results in the SNMPD process resetting due to lack of memory.
Workaround
: This issue is resolved.
CSCsr02430
Symptom
: After issuing the
show boot
command, there are duplicate image names listed in the switch
output as shown below:
switch# show boot
sup-1
kickstart variable not set
system variable = bootflash:/m9500-sf1ek9-mzg.3.4.1.bin;bootflash:/m9500-sf1ek9-
mzg.3.4.1.bin
sup-2
kickstart variable not set
system variable = bootflash:/m9500-sf1ek9-mzg.3.4.1.bin;bootflash:/m9500-sf1ek9-
mzg.3.4.1.bin
No module boot variable set
switch#
This occurs if you issue the boot system command twice with the same image name as shown below:
switch(config)# boot system bootflash:m9500-sf1ek9-mzg.3.4.1.bin
switch(config)# boot system bootflash:m9500-sf1ek9-mzg.3.4.1.bin
Workaround
: This issue is resolved.
CSCsq64637
Symptom
: All device aliases in Fabric Manager disappear when adding new device aliases.