HP Cisco Nexus 5000 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS R - Page 45

Workaround, Symptom, show ivr internal dep, ivr withdraw, domain, ivr refresh

Page 45 highlights

Caveats Send documentation comments to [email protected] Workaround: Bring up multiple links between two switches one at a time. Verify that the first link came up correctly before attempting to bring up the next link. If the first link fails to come up because of a domain ID overlap, resolve the domain conflict and then try again to bring up the links. • CSCsi72048 Symptom: FCIP links may fail on an MDS 9216i switch that has compression set to auto when the other end of the FCIP link is terminated by an IPS-8 module. You may see the following message in the logs: %IPS_SB_MGR-SLOT1-3-CRYPTO_FAILURE: Heartbeat failure in encryption engine (error 0x1) %ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface GigabitEthernet1/1 is down (Port software failure) %PORT-5-IF_DOWN_SOFTWARE_FAILURE: %$VSAN 1%$ Interface fcip99 is down (Port software failure) Workaround: If both ends of an FCIP link are not on an MPS-14/2 module, do not use mode 1 and auto. • CSCsk43922 Symptom: A data path processor (DPP) might fail on an MDS switch running SSI Release 3.2(1) on the SSM. The failure occurs after several days of running traffic when a misbehaving target sends unexpected frames well after the response has already been received from the same target. Workaround: None. • CSCsk49029 Symptom: If there is a request to export a domain while the same domain is being cleaned up, domain entries might not be programmed. As a result, communication between IVR devices might not occur. Workaround: Because the programming request was lost, the only way to retrigger the programming is to withdraw the domain and refresh IVR. Follow these steps: 1. Identify domains with problem using the show ivr internal dep command. switch# show ivr internal dep Internal information for DEP FSM vsan domain nh status sync_status req i/f 101 0x61(97) 1001 ALL_DONE OXID|FCID_RW 0 [ fc3/2 ] 102 0x62(98) 1002 ALL_DONE OXID|FCID_RW 0 [ fc3/5 ] 1001 0x9e(158) 101 NONE OXID|FCID_RW 0 [ fc2/16 ] 1002 0x98(152) 102 ALL_DONE OXID|FCID_RW 0 [ fc9/10] Number of DEP entries : 4 After waiting for a few minutes for IVR to stabilize, if the status column for the {VSAN, domain} combination is NONE, then this problem has occurred the switch. 2. Withdraw the troubled domains using the ivr withdraw domain domain vsan vsan-id command. 3. Readvertise the withdrawn domains using the ivr refresh command. • CSCsk49634 Symptom: In rare cases, an FCIP link might flap on a network with high latency and a consistently high loss rate. Workaround: None. OL-14116-10 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2) 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

Send documentation comments to [email protected]
45
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2)
OL-14116-10
Caveats
Workaround
: Bring up multiple links between two switches one at a time. Verify that the first link
came up correctly before attempting to bring up the next link. If the first link fails to come up
because of a domain ID overlap, resolve the domain conflict and then try again to bring up the links.
CSCsi72048
Symptom
: FCIP links may fail on an MDS 9216i switch that has compression set to auto when the
other end of the FCIP link is terminated by an IPS-8 module. You may see the following message in
the logs:
%IPS_SB_MGR-SLOT1-3-CRYPTO_FAILURE: Heartbeat failure in encryption engine (error
0x1)
%ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface GigabitEthernet1/1 is down (Port
software failure)
%PORT-5-IF_DOWN_SOFTWARE_FAILURE: %$VSAN 1%$ Interface fcip99 is down (Port software
failure)
Workaround
: If both ends of an FCIP link are not on an MPS-14/2 module, do not use mode 1 and
auto.
CSCsk43922
Symptom
: A data path processor (DPP) might fail on an MDS switch running SSI Release 3.2(1)
on the SSM. The failure occurs after several days of running traffic when a misbehaving target sends
unexpected frames well after the response has already been received from the same target.
Workaround
: None.
CSCsk49029
Symptom
: If there is a request to export a domain while the same domain is being cleaned up,
domain entries might not be programmed. As a result, communication between IVR devices might
not occur.
Workaround
: Because the programming request was lost, the only way to retrigger the
programming is to withdraw the domain and refresh IVR. Follow these steps:
1.
Identify domains with problem using the
show ivr internal dep
command.
switch#
show ivr internal dep
Internal information for DEP FSM
--------------------------------
vsan domain nh status sync_status req i/f
101 0x61(97) 1001 ALL_DONE OXID|FCID_RW 0 [ fc3/2 ]
102 0x62(98) 1002 ALL_DONE OXID|FCID_RW 0 [ fc3/5 ]
1001 0x9e(158) 101 NONE OXID|FCID_RW 0 [ fc2/16 ]
1002 0x98(152) 102 ALL_DONE OXID|FCID_RW 0 [ fc9/10]
Number of DEP entries : 4
After waiting for a few minutes for IVR to stabilize, if the status column for the {VSAN, domain}
combination is NONE, then this problem has occurred the switch.
2.
Withdraw the troubled domains using the
ivr withdraw
domain
domain
vsan
vsan-id
command.
3.
Readvertise the withdrawn domains using the
ivr refresh
command.
CSCsk49634
Symptom
: In rare cases, an FCIP link might flap on a network with high latency and a consistently
high loss rate.
Workaround
: None.