HP Cisco Nexus 5000 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS R - Page 47

Symptom, Workaround, Continue, On Solaris 8

Page 47 highlights

Caveats Send documentation comments to [email protected] • CSCso41087 Symptom: If FCIP is enabled and the SAN-OS is upgraded, the SNMP service will run into exception and the following syslog message is displayed: SNMP Operation(165) failed (62) setting error index. Workaround: Disable FCIP during the SAN-OS upgrade. • CSCsq29607 Symptom: After logging back into Fabric Manager Client, clicking on the Summary tab causes a disconnect. Workaround: Exit from Fabric Manager Client then restart Fabric Manager Client and log in again. • CSCsq44360 Symptom: When the startup rising alarm is triggered, the sample value is smaller than the rising threshold. This should not trigger an alarm. Workaround: None. • CSCsq78868 Symptom: Flow statistics on a Generation 2 module may not be accurate if any of the flows that participate in flow statistics on the module have multiple FSPF paths. Workaround: For all flows that have flow statistics configured on that module, make sure there is only one available FSPF path. Use port-channel instead of multiple links to achieve more bandwidth. • CSCsr22782 Symptom: On Solaris 8, 9, and 10 and RedHat Linux AS4 (kernel version 2.6) the Fabric Manager Release 3.4(1) installer displays a warning message indicating that it is an unsupported platform. This occurs even though these platforms are supported. Workaround: Ignore the warning message and click Continue. • CSCsr89410 Symptom: An FCIP link may flap due to a watchdog timeout condition when FCIP Tape Acceleration is running inSAN-OS Release 3.3(1c). Workaround: Disable FCIP Tape Acceleration. • CSCsr92585 Symptom: An FCIP link running with Tape Acceleration may flap when the host is attempting SRR/REC tape error handling. Workaround:None. If link stability is needed, disable FCIP Tape Acceleration. • CSCin95789 Symptom: When you configure Cisco Traffic Analyzer to capture traffic on one or more interfaces on a Windows platform, the configuration web page might not show that the interface has been selected for traffic capture even though traffic capture on that interface is enabled. Workaround: Check the logs to clarify that the correct interface has been selected. • CSCse31881 Symptom: If there are IP over Fibre Channel (IPFC) interfaces configured on an SSM, you might experience issues if you downgrade from SAN-OS Release 3.x to Release 2.x. Workaround: Before downgrading, remove the IPFC interface on the module and then recreate the IPFC interface after the downgrade is complete. OL-14116-10 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2) 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

Send documentation comments to [email protected]
47
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2)
OL-14116-10
Caveats
CSCso41087
Symptom
: If FCIP is enabled and the SAN-OS is upgraded, the SNMP service will run into
exception and the following syslog message is displayed:
SNMP Operation(165) failed (62)
setting error index
.
Workaround
: Disable FCIP during the SAN-OS upgrade.
CSCsq29607
Symptom
: After logging back into Fabric Manager Client, clicking on the Summary tab causes a
disconnect.
Workaround
: Exit from Fabric Manager Client then restart Fabric Manager Client and log in again.
CSCsq44360
Symptom
: When the startup rising alarm is triggered, the sample value is smaller than the rising
threshold. This should not trigger an alarm.
Workaround
: None.
CSCsq78868
Symptom
: Flow statistics on a Generation 2 module may not be accurate if any of the flows that
participate in flow statistics on the module have multiple FSPF paths.
Workaround
: For all flows that have flow statistics configured on that module, make sure there is
only one available FSPF path. Use port-channel instead of multiple links to achieve more bandwidth.
CSCsr22782
Symptom
: On Solaris 8, 9, and 10 and RedHat Linux AS4 (kernel version 2.6) the Fabric Manager
Release 3.4(1) installer displays a warning message indicating that it is an unsupported platform.
This occurs even though these platforms are supported.
Workaround
: Ignore the warning message and click
Continue
.
CSCsr89410
Symptom
: An FCIP link may flap due to a watchdog timeout condition when FCIP Tape
Acceleration is running inSAN-OS Release 3.3(1c).
Workaround
: Disable FCIP Tape Acceleration.
CSCsr92585
Symptom
: An FCIP link running with Tape Acceleration may flap when the host is attempting
SRR/REC tape error handling.
Workaround
:None. If link stability is needed, disable FCIP Tape Acceleration.
CSCin95789
Symptom
: When you configure Cisco Traffic Analyzer to capture traffic on one or more interfaces
on a Windows platform, the configuration web page might not show that the interface has been
selected for traffic capture even though traffic capture on that interface is enabled.
Workaround
: Check the logs to clarify that the correct interface has been selected.
CSCse31881
Symptom
: If there are IP over Fibre Channel (IPFC) interfaces configured on an SSM, you might
experience issues if you downgrade from SAN-OS Release 3.x to Release 2.x.
Workaround
: Before downgrading, remove the IPFC interface on the module and then recreate the