Control-panel message 59.X Error Turn off then on Status alert 59.X Error Turn off then on 59.X Error Turn off then on 59.X Error Turn off then on Description Recommended action The product has experienced a 1. Reconnect the connector problem with one of the motors. (J516) on the fuser motor ● 59.3 Fuser motor startup error and the connector (J81) on the DC controller PCA. ● 59.4 Fuser motor rotation 2. Run the fuser motor drive test in the actuator drive error mode to verify that the fuser motor is functioning correctly. If it is not, replace the fuser motor unit. Image drum motor startup or rotation error-black. ● 59.50 Image drum motor startup error-black ● 59.60 Image drum motor rotation error-black 1. Reconnect the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA. 2. Run the drum motor drive test in the actuator drive mode to verify that the ITB motor is functioning correctly. If it is not, replace the ITB motor unit. Image drum motor startup or 1. Reconnect the connector rotation error-cyan, magenta, or (J515) on the drum motor yellow. and the connector (J81) on ● 59.51 Image drum motor the DC controller PCA. startup error-cyan 2. Run the drum motor drive ● 59.52 Image drum motor test in the actuator drive mode to verify that the drum startup error-magenta motor is functioning ● 59.53 Image drum motor startup error-yellow correctly. If it is not, replace the drum motor unit. ● 59.61 Image drum motor rotation error-cyan ● 59.62 Image drum motor rotation error-magenta ● 59.63 Image drum motor rotation error-yellow Black developer motor startup or 1. rotation error. ● 59.70 Black developer motor startup error 2. ● 59.80 Black developer motor rotation error Reconnect the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA. Run the ITB motor drive test in the actuator drive mode to verify that the ITB motor is functioning correctly. If it is not, replace the ITB motor unit. 224 Chapter 3 Solve problems ENWW