HP DL560 HP ProLiant DL560 Server Maintenance and Service Guide - Page 25
Hot-Plug Fan
UPC - 808736876919
View all HP DL560 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
26 HP ProLiant DL560 Server Maintenance and Service Guide CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. 2. Remove the power supply blank. To replace a power supply blank: 1. Slide the power supply blank into the bay until it locks into place. 2. Swing the cable management arm into place and lock it. Hot-Plug Fan To remove the component: 1. Extend or remove the server from the rack ("Extending the Server from the Rack" on page 15, "Removing the Server from the Rack" on page 16). 2. Remove the access panel ("Removing the Access Panel" on page 17). 3. Determine whether the fan is operating with redundancy: − If the fan zone is not operating with redundancy, power down the server ("Powering Down the Server" on page 14). − If the fan zone is operating with redundancy, continue with the next step.