HP P2000 HP P2000 G3 MSA System CLI Reference Guide - Page 388
Table 62, Excessive PHY changes
View all HP P2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 388 highlights
Table 62 sas-status-controller-a properties (continued) Name Type Description elem-reasonnumeric change-counter code-violations disparityerrors crc-errors conn-crc-errors lost-dwords invalid-dwords reset-errorcounter flag-bits string Numeric equivalents for elem-reason values. • 0: (blank) • 32769: Error count interrupts • 32770: Externally disabled • 32771: PHY control • 32772: Not ready • 32773: Firmware reboot • 32774: Drive removed • 32775: Unused - disabled by default • 32776: Excessive PHY changes uint32 Number of times PHY status has changed. uint32 Number of code violations. uint32 Number of disparity errors. uint32 Number of CRC (cyclic redundancy check) errors uint32 Number of connection CRC errors. uint32 Number of lost double words. uint32 Number of invalid double words. uint32 Number of times error counters have been reset. uint32 PHY status flag bits. Example # show expander-status ... 0 A 1 0 Drive 1 Enabled - Healthy 1 OK 1 Enabled 0 0 00000003 00000000 00000000 00000000 00000000 00000000 00000000 00000000 20002025 ... 388 XML API basetype properties