HP P3410A HP NetRAID Series User Guide - Page 61

Battery Backup HP NetRAID-3Si Adapters and Optional for Integrated HP NetRAID, in HP NetServer LH

Page 61 highlights

Chapter 3 HP NetRAID Config eight bits. This setting is required if the selected SCSI channel is terminated with 8-bit devices at both ends. • Terminate Wide Channel: Enables Wide termination for the selected channel. This is required if the HP NetRAID Series adapter is at one end of the SCSI bus for the selected channel. The default setting is Wide Termination. • Disable Termination: Disables termination on the adapter for the selected channel. This option should be used if the selected SCSI channel is terminated with Wide devices at both ends. • View Parameters: Displays the termination and active status of the selected channel. Battery Backup (HP NetRAID-3Si Adapters and Optional for Integrated HP NetRAID in HP NetServer LH 3000/3000r, LH 6000/6000r, and LT 6000r Only) View the Battery Backup properties from this option. The properties of your Battery Backup Unit (in HP NetRAID-3Si) or Battery Backup Module (optional for integrated HP NetRAID in HP NetServer LH 3000/3000r, LH 6000/6000r, and LT 6000r) should be identical or similar to the following properties: • Battery Card Present • Battery Pack Present • Temperature Good • Voltage Good • Fast Charging Completed • Charge Counter 1 ◊ Reset Charge Count Cycles ∗ Yes ∗ No This menu item produces an error message (missing battery) if accessed with the HP NetRAID-1Si adapter or with an integrated HP NetRAID controller without battery backup. Disregard the message for these cases. 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161

Chapter 3
HP NetRAID Config
55
eight bits. This setting is required if the selected SCSI channel is
terminated with 8-bit devices at both ends.
Terminate Wide Channel
: Enables Wide termination for the selected
channel. This is required if the HP NetRAID Series adapter is at one end of
the SCSI bus for the selected channel. The default setting is Wide
Termination.
Disable Termination
: Disables termination on the adapter for the selected
channel. This option should be used if the selected SCSI channel is
terminated with Wide devices at both ends.
View Parameters
: Displays the termination and active status of the
selected channel.
Battery Backup (HP NetRAID-3Si Adapters and Optional for Integrated HP NetRAID
in HP NetServer LH 3000/3000r, LH 6000/6000r, and LT 6000r Only)
View the Battery Backup properties from this option. The properties of your
Battery Backup Unit (in HP NetRAID-3Si) or Battery Backup Module (optional
for integrated HP NetRAID in HP NetServer LH 3000/3000r, LH 6000/6000r, and
LT 6000r) should be identical or similar to the following properties:
Battery Card
Present
Battery Pack
Present
Temperature
Good
Voltage
Good
Fast Charging
Completed
Charge Counter
1
Reset Charge Count Cycles
Yes
No
This menu item produces an error message (missing battery) if accessed with the
HP NetRAID-1Si adapter or with an integrated HP NetRAID controller without
battery backup. Disregard the message for these cases.