HP ProLiant 4500 Compaq ProLiant 4500 Servers Maintenance and Service Guide - Page 45
Drive Array - Drives
View all HP ProLiant 4500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
3-12 Diagnostic Tools POST Error Messages Continued Error Code Beeps 1796-Drive Array - Array Accelerator Not Responding. Array Accelerator is temporarily disabled. None 1797-Drive Array - Array Accelerator Read Error Occurred. Data in Array Accelerator has been lost. Array Accelerator is disabled. 1798-Drive Array - Array Accelerator Write Error Occurred. Array Accelerator is disabled. 1799-Drive Array - Drive(s) Disabled due to Array Accelerator Data Loss. Select "F1" to continue with logical drives disabled. Select "F2" to accept data loss and to re-enable logical drives. None None None 2L,2S (Run System Configuration None Utility = "F10" key) (RESUME = "F1" KEY) None Probable Source of Problem Array Accelerator is defective or has been removed. Hard parity error while reading data from posted writes memory. Hard parity error while writing data to posted writes memory. Volume failed due to loss of data in posted-writes memory. Power is cycled. Temperature too hot. Processor fan not installed or spinning. A configuration error occurred during POST. As indicated to continue. Action 1. Check that the Array Accelerator is properly seated. 2. Run the System Configuration Utility to re-configure the Compaq IDA-2 without the Array Accelerator. Enable Array Accelerator. Enable Array Accelerator. Press F1 to continue with logical drives disabled or F2 to accept data loss and re-enable logical drive. Check fans. Press F10 to run System Configuration Utility. Press the F1 key. Maintenance and Service Guide