HP ProLiant 4500 Compaq ProLiant 4500 Servers Maintenance and Service Guide - Page 62

Controller reported POST error. Error Code

Page 62 highlights

Diagnostic Tools 3-29 Controller firmware needs upgrading The controller firmware is below the latest recommended version. Call your Authorized Compaq Reseller to obtain the latest upgraded firmware. Controller firmware needs upgrading (DAAD Error 102) You have the correct controller, however, the IDA firmware should be greater than 1.26. Call your Authorized Compaq Reseller to obtain the latest firmware. Controller is not configured The controller is not configured. If the controller was previously configured and you change drive locations, there may be a problem with the placement of the drives. DAAD examines each physical drive and looks for drives that have been moved to a different drive bay. Look for the messages that indicate which drives have been moved. If none appear and drive swapping did not occur, run the System Configuration Utility to configure the controller and nonvolatile RAM. Do not run the System Configuration Utility if you believe drive swapping has occurred. Controller needs replacing (DAAD Error 102) The IDA firmware is less than version 0.96. Replace the controller as soon as possible. Controller needs replacing (DAAD Error 104) The Intelligent Array Expansion System firmware is less than version 1.14. Replace the controller as soon as possible. Controller reported POST error. Error Code: x The controller returned an error from its internal Power-On Self Tests. Replace the controller. Controller restarted with a signature of zero DAAD did not find a valid configuration signature to use to get the data. Nonvolatile RAM may not be present (unconfigured) or the signature present in nonvolatile RAM may not match the signature on the controller. Run the System Configuration Utility to configure the controller and nonvolatile RAM. Disable command issued Posted writes have been disabled by the issuing of the Accelerator Disable command. This occurred because of an operating system device driver. Restart the system. Run the System Configuration Utility to reinitialize the array accelerator board. Drive (bay) X needs replacing (DAAD Error 102) The 210-megabyte hard drive installed in the computer has firmware version 2.30 or 2.31. Replace the drive. Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

Diagnostic Tools
3-29
Maintenance and Service Guide
Controller firmware needs upgrading
The controller firmware is below the latest recommended version.
Call your Authorized Compaq Reseller to obtain the latest upgraded firmware.
Controller firmware needs upgrading
(DAAD Error 102)
You have the correct controller, however, the IDA firmware should be greater than 1.26.
Call your Authorized Compaq Reseller to obtain the latest firmware.
Controller is not configured
The controller is not configured. If the controller was previously configured and you change
drive locations, there may be a problem with the placement of the drives. DAAD examines
each physical drive and looks for drives that have been moved to a different drive bay.
Look for the messages that indicate which drives have been moved. If none appear and drive
swapping did not occur, run the System Configuration Utility to configure the controller and
nonvolatile RAM.
Do not
run the System Configuration Utility if you believe drive swapping
has occurred.
Controller needs replacing (DAAD Error 102)
The IDA firmware is less than version 0.96.
Replace the controller as soon as possible.
Controller needs replacing (DAAD Error 104)
The Intelligent Array Expansion System firmware is less than version 1.14.
Replace the controller as soon as possible.
Controller reported POST error. Error Code:
x
The controller returned an error from its internal Power-On Self Tests.
Replace the controller.
Controller restarted with a signature of zero
DAAD did not find a valid configuration signature to use to get the data. Nonvolatile RAM
may not be present (unconfigured) or the signature present in nonvolatile RAM may not
match the signature on the controller.
Run the System Configuration Utility to configure the controller and nonvolatile RAM.
Disable command issued
Posted writes have been disabled by the issuing of the Accelerator Disable command. This
occurred because of an operating system device driver.
Restart the system. Run the System Configuration Utility to reinitialize the array
accelerator board.
Drive (bay)
X
needs replacing (DAAD Error 102)
The 210-megabyte hard drive installed in the computer has firmware version 2.30 or 2.31.
Replace the drive.