Informative Examples Of Protective Devices In Single - Phase

Page 6 highlights

ENGLISH SAFETY GUIDELINES(continued) Caution You may have serious injury or your property may be damaged unless you follow the instruction below. Do not bundle the power cord. It will be heated up or it may cause a fire. Caution for 200 - 240V operation only This equipment relies on the protective devices in the building installation for short circuit and over - current protection. Refer to the following table for the suitable number and location of the protective devices which should be provided in the building installation. INFORMATIVE EXAMPLES OF PROTECTIVE DEVICES IN SINGLE - PHASE EQUIPMENT OR SUB - ASSEMBLIES Protection against Case A: Equipment to be connected to POWER SYSTEMS with earthed neutral reliably identified, except for Case C below. Earth faults Overcurrent Case B: Equipment to be connected to any supply, Earth faults including IT POWER SYSTEMS and supplies with reversible Overcurrent plugs, except for Case C below. Case C: Equipment to be connected to 3 - wire power systems with earthed neutral reliably identified. Earth faults Overcurrent Minimum number of fuses or circuit - breaker poles 1 1 2 1 2 2 Location Phase conductor Either of the two conductors Both conductors Either of the two conductors Each phase conductor Each phase conductor Verify that the protective devices in the building installation meets the conditions in the table prior to installing the equipment. Remove the power cord for complete isolation! For complete isolation from the power source, remove the power cord from the monitor or from the wall socket. vi

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

vi
ENGLISH
You may have serious injury or your property may be damaged unless
you follow the instruction below.
Caution
Do not bundle the power cord.
It will be heated up or it may cause a fire.
Caution for 200 - 240V operation only
This equipment relies on the protective devices in the building installation for short -
circuit and over - current protection. Refer to the following table for the suitable number
and location of the protective devices which should be provided in the building
installation.
INFORMATIVE EXAMPLES OF PROTECTIVE DEVICES IN SINGLE - PHASE
EQUIPMENT OR SUB - ASSEMBLIES
Verify that the protective devices in the building installation meets the conditions in
the table prior to installing the equipment.
Remove the power cord for complete isolation!
For complete isolation from the power source, remove the power cord from the monitor
or from the wall socket.
Protection
against
Minimum number
of fuses or circuit -
breaker poles
Location
Case A: Equipment to be
connected to POWER
SYSTEMS with earthed
neutral reliably identified,
except for Case C below.
Earth faults
1
Phase conductor
Overcurrent
1
Either of the two
conductors
Case B: Equipment to be
connected to any supply,
including IT POWER SYSTEMS
and supplies with reversible
plugs, except for Case C below.
Earth faults
2
Both conductors
Overcurrent
1
Either of the two
conductors
Case C: Equipment to be
connected to 3 - wire power
systems with earthed neutral
reliably identified.
Earth faults
2
Each phase
conductor
Overcurrent
2
Each phase
conductor
SAFETY GUIDELINES(continued)