Hitachi HTS541040G9AT00 Specifications - Page 173
Sense Condition F0h: vendor specific
UPC - 000059826569
View all Hitachi HTS541040G9AT00 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 173 highlights
13.33 Sense Condition (F0h: vendor specific) Table 111: Sense Condition (F0h: vendor specific) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature 0 0 0 0 0 0 0 1 Sector Count LBA Low LBA Mid LBA High Device 1 - 1 D - - - - Command 1 1 1 1 0 0 0 0 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error see below Sector Count V V V V V V V V LBA Low N LBA Mid LBA High Device - - - D - - - - Status see below 76 CRC UNC 00 Error Register 54 3 2 1 0 0 IDN 0 ABT T0N AMN 0V 0 V 0 0 Status Register 7 654 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR V VV- V - - V The Sense Condition command is used to sense temperature in a device. This command is executable without spinning up even if a device is started with No Spin Up option. If this command is issued at the temperature out of range which is specified for operating condition, the error might be returned with IDN bit 1. Output parameters to the device Feature The Feature register must be set to 01h. All other values are rejected with setting ABORT bit in status register. Input parameters from the device Sector Count The Sector Count register contains result value. Value Description 00h Temperature is equal to or lower than -20°C 01h-FEh Temperature is (Value/2-20)°C FFh Temperature is higher than 107°C N Not recommendable condition for start up. If over stressed condition is detected, this bit will be set to one. Travelstar 5K100 Hard Disk Drive Specification 159