Notes For Conventional Heating And Cooling Systems
UPC - 085267256865
View all Honeywell RTH8500D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Step 7. Connect Wires to New Wallplate (Cont) NOTES FOR CONVENTIONAL HEATING AND COOLING SYSTEMS 1 If wires will be connected to both RC and R on the new thermostat, remove metal jumper wire between RC and R. Leave metal jumper wire in place if only one of the terminals, RC or R, will be connected on the new thermostat. 2 If wires were connected to both R and RH terminals on the old thermostat, remove metal jumper wire between RC and R on the new thermostat. Connect the old R to the new RC and the old RH to the new R. 3 If two C and/or C1 wires were connected to the old thermostat, do not connect them to the new thermostat. Wrap the bare end of each wire separately with electrical tape and do not use. 4 If one C and/or C1 wire was connected to the old thermostat, the wire should be connected to the "C" letter designation on the new thermostat. M22246 69-1725-1 18