Icom IC-7000 Service Manual - Page 28
RECEIVER ADJUSTMENT continue, Tuned BPF170 M, Total Gain144M/430M, S0 LevelWFM - sensitivity
View all Icom IC-7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
4-5 RECEIVER ADJUSTMENT (continue) ADJUSTMENT ADJUSTMENT CONDITION DISPLAY OPERATION RECEIVE 6 • Set an SSG as ; SENSITIVITY Frequency : 169.8015 MHz (VHF/UHF) • Receiving Tuned BPF(170 M) Push [F-4 (SET)]. 7 • Set an SSG as ; Frequency : 400.2015 MHz • Receiving Tuned BPF(400 M) Push [F-4 (SET)]. 8 • Set an SSG as ; Frequency : 435.2015 MHz • Receiving Tuned BPF(435 M) Push [F-4 (SET)]. 9 • Set an SSG as ; Frequency : 469.8015 MHz • Receiving Tuned BPF(470 M) Push [F-4 (SET)]. RX TOTAL GAIN (VHF/UHF) 1 • Connect an SSG to [ANT2] con- nector and set as; Frequency : 435.2015 MHz Level : 500 µV* (-53 dBm) or OFF Modulation : OFF • Connect an AC millivolt meter to [EXT SP] jack with an 8 Ω load. • Receiving Total Gain(144M/430M) Set 25 dB of AF level difference between 500 µV and no signal input from the SSG using with [DIAL]. Then push [F-4 (SET)]. S-METER (WFM) 1 • Connect an SSG to the [ANT2] connector and set as; Frequency : 90.80 MHz Level : 0.56 µV* (-112 dBm) Modulation : OFF • Receiving S0 Level(WFM) Push [F-4 (SET)]. 2 • Set an SSG as; Level : 3.2 µV* (-97 dBm) • Receiving S9 Level(WFM) Push [F-4 (SET)]. 3 • Set an SSG as; Level : 32 µV* (-77 dBm) • Receiving S9+60 Level(WFM) Push [F-4 (SET)]. After the adjustment, exit the adjustment mode. ADJUSTMENT ADJUSTMENT CONDITION MEASUREMENT UNIT LOCATION VALUE ADJUSTMENT UNIT ADJUST WFM 1 • Operating freq : 90.00000 MHz DISTORTION MODE : WFM Preamp : ON • Connect an SSG to [ANT2] con- nector and set as; Frequency : 90.0000 MHz Level : 3.2 µV* (-97 dBm) Modulation : 1 kHz Deviation : 50 kHz • Receiving REAR Connect a distortion me- M i n i mu m A F panel ter to [EXT SP] jack with distortion level an 8 Ω load. MAIN C1423 *The output level of a standard signal generator (SSG) is indicated as SSG's open circuit. 4 - 13