Intel MFS5000SI User Guide - Page 47

Removing a Mezzanine Card, Securing Mezzanine Card to Standoffs

Page 47 highlights

9. Secure the mezzanine card to the standoffs with the four screws previously removed. 1 I/O 2 1 2 ID AF002458 Figure 38. Securing Mezzanine Card to Standoffs 10. Reinstall the top cover. For instructions, see "Replacing and Closing the Top Cover" on page 10. 11. Reinstall the server compute blade in the server system. For instructions, see "Installing a Compute Module into the Server System" on page 8. Removing a Mezzanine Card 1. Observe the safety and ESD information at the beginning of this manual and in the appendices. 2. If the compute module is installed in a server system, see "Removing a Compute Module from the Server System" on page 7 for removal instructions. 3. Remove the top cover. For instructions, see "Opening and Removing the Top Cover" on page 8. Intel® Compute Module MFS5000SI User Guide 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Intel® Compute Module MFS5000SI User Guide
35
9.
Secure the mezzanine card to the standoffs with the four screws previously removed.
Figure 38.
Securing Mezzanine Card to Standoffs
10. Reinstall the top cover. For instructions, see
“Replacing and Closing the Top Cover”
on page 10
.
11. Reinstall the server compute blade in the server system. For instructions, see
“Installing a Compute Module into the Server System” on page 8
.
Removing a Mezzanine Card
1.
Observe the safety and ESD information at the beginning of this manual and in the
appendices.
2.
If the compute module is installed in a server system, see
“Removing a Compute
Module from the Server System” on page 7
for removal instructions.
3.
Remove the top cover. For instructions, see
“Opening and Removing the Top Cover”
on page 8
.
1
I/O
2
ID
1
2
AF002458
1
I/O
2
ID
1
2