Intel MFS5000SI User Guide - Page 52

CMOS Battery Location, correct polarity, insert it in the battery socket.

Page 52 highlights

4. Locate the DMOS battery (see letter "A" in the following figure). A AF002455 Figure 42. CMOS Battery Location 5. Insert the tip of a small flat-head screwdriver, or equivalent, under the tab in the plastic retainer. Gently push down on the screwdriver to lift the battery. 6. Remove the battery from its socket. 7. Dispose of the battery according to local ordinance. 8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Replace the top cover. For instructions, see "Replacing and Closing the Top Cover" on page 10. 10. Reinstall the server compute blade in the server system. For instructions, see "Installing a Compute Module into the Server System" on page 8 11. Run Setup to restore the configuration settings to the RTC. 40 Intel® Compute Module MFS5000SI User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

40
Intel® Compute Module MFS5000SI User Guide
4.
Locate the DMOS battery (see letter “A” in the following figure).
Figure 42.
CMOS Battery Location
5.
Insert the tip of a small flat-head screwdriver, or equivalent, under the tab in the
plastic retainer. Gently push down on the screwdriver to lift the battery.
6.
Remove the battery from its socket.
7.
Dispose of the battery according to local ordinance.
8.
Remove the new lithium battery from its package, and, being careful to observe the
correct polarity, insert it in the battery socket.
9.
Replace the top cover. For instructions, see
“Replacing and Closing the Top Cover”
on page 10
.
10. Reinstall the server compute blade in the server system. For instructions, see
“Installing a Compute Module into the Server System” on page 8
11. Run Setup to restore the configuration settings to the RTC.
AF002455
A