Configuration Jumpers - s3420gplc bios

Page 25 highlights

Configuration Jumpers BMC Force Update 2 J1A2 3 Default Enabled ME Force Update 2 J1F1 3 Default Enabled BIOS Recovery 2 J1F3 3 Default Recover Password Clear 2 J1F2 3 Default Password Clear CMOS Clear 2 J1F5 3 Default CLEAR CMOS Jumper Name Pins J1A2: BMC Force Update 1-2 (Intel® Server Board S3420GPLX and S3420GPLC) 2-3 J1F2: Password Clear 1-2 2-3 J1F5: CMOS Clear 1-2 2-3 J1F3: BIOS Recovery 1-2 2-3 What will occur during a system reset.. BMC Firmware Force Update Mode - Disabled (Default) BMC Firmware Force Update Mode - Enabled These pins should have a jumper in place for normal system operation. (Default) If these pins are jumpered, administrator and user passwords will be cleared on the next reset. NOTE: These pins should not be jumpered for normal operation. These pins should have a jumper in place for normal system operation. (Default) If these pins are jumpered, the CMOS settings are cleared on the next reset. NOTE: These pins should not be jumpered for normal operation. These pins should have a jumper in place for normal system operation. (Default) The main system BIOS will not boot with these pins jumpered. NOTE: The system will boot from EFI-bootable recovery media with a recovery BIOS image. Intel® Server Board S3420GP User Guide 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Intel® Server Board S3420GP User Guide
23
Configuration Jumpers
3
2
Default
CLEAR
CMOS
J1F5
CMOS
Clear
3
2
Default
Password
Clear
J1F2
Password
Clear
3
2
Default
Recover
J1F3
BIOS
Recovery
3
2
Default
Enabled
J1F1
ME
Force
Update
3
2
Default
Enabled
J1A2
BMC
Force
Update
Jumper Name
Pins
What will occur during a system reset..
J1A2: BMC Force Update
(Intel
®
Server Board
S3420GPLX and
S3420GPLC)
1-2
BMC Firmware Force Update Mode — Disabled (
Default
)
2-3
BMC Firmware Force Update Mode — Enabled
J1F2: Password Clear
1-2
These pins should have a jumper in place for normal system
operation. (
Default
)
2-3
If these pins are jumpered, administrator and user passwords will
be cleared on the next reset.
NOTE:
These pins should not be jumpered for normal operation.
J1F5: CMOS Clear
1-2
These pins should have a jumper in place for normal system
operation. (
Default
)
2-3
If these pins are jumpered, the CMOS settings are cleared on the
next reset.
NOTE:
These pins should
not
be jumpered for normal operation.
J1F3: BIOS Recovery
1-2
These pins should have a jumper in place for normal system
operation. (
Default
)
2-3
The main system BIOS will not boot with these pins jumpered.
NOTE:
The system will boot from EFI-bootable recovery media
with a recovery BIOS image.