Invacare TDXSR-CG-HD Owners Manual - Page 84

Composite/Articulating Footplate Heel, Loop Replacement

Page 84 highlights

7 SETUP/MAINTENANCE 7.8 Composite/Articulating Footplate Heel Loop Replacement Disassembly Composite 1. Remove the mounting screw and coved washer that secures the lower half of the footrest to the swingaway footrest assembly. 2. Remove the lower footrest assembly. 3. Remove the mounting screw and locknut that secure the heel loop to the footrest. 4. Slide heel strap over cane of footrest assembly. Articulating 1. Remove the two mounting screws that secure the heel loop to the articulating footplate. Assembly 1. Replace heel strap/loop. 2. Reverse steps in Disassembly to assemble.  When securing heel loop to the footrest assembly, tighten mounting screw until the spacer is secure. Composite Cane of Footrest Assembly Mounting Screw Spacer Composite Footplate Locknut Articulating Mounting Screw Heel Loop Articulating Footplate FIGURE 5 Composite/Articulating Footplate Heel Loop Replacement Invacare® Formula™ CG Seating 84 Part No 1143155

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

7
SETUP/MAINTENANCE
Invacare® Formula™ CG Seating
84
Part No 1143155
7.8
Composite/Articulating Footplate Heel
Loop Replacement
Disassembly
Composite
1.
Remove the mounting screw and coved washer that secures the
lower half of the footrest to the swingaway footrest assembly.
2.
Remove the lower footrest assembly.
3.
Remove the mounting screw and locknut that secure the heel loop
to the footrest.
4.
Slide heel strap over cane of footrest assembly.
Articulating
1.
Remove the two mounting screws that secure the heel loop to the
articulating footplate.
Assembly
1.
Replace heel strap/loop.
2.
Reverse steps in Disassembly
to assemble.
FIGURE 5
Composite/Articulating Footplate Heel Loop
Replacement
When securing heel loop to the footrest assembly,
tighten mounting screw until the spacer is secure.
Composite
Articulating
Mounting Screw
Spacer
Composite
Footplate
Locknut
Mounting Screw
Heel Loop
Articulating
Footplate
Cane of Footrest Assembly