LG ARUN096BT2 Installation Manual - Page 13

Installation Space

Page 13 highlights

ENGLISH Installation Space Installation Space Individual Installation s Basic space required A space of at least 250mm(9-13/16 inch) is necessary at the back for inlet air. Taking servicing, etc. from the rear into account, a space of about 915mm(36 inches) should be provided, the same as at the front. C A 915mm(36 inches) or more (Control box is open/close type) B 250mm(9-13/16 inch) or more C Top discharge (open in principle) D Front inlet (open in principle) D E Rear inlet (open in principle) Rear Side B E Front Side A Control Box < Side view > < Top view > Rear Side B Rear Side B Control Box Control Box Front Side A s When inlet air enters from right and left sides of unit A 915mm(36 inches) or more (Control box is open/close type) B 250mm(9-13/16 inch) or more C 150mm(5-7/8 inch) from the wall A B CAUTION Wall height(H) must not exceed height of the product. If the wall height is higher than the whole height of product by (h), Add (h) to , . < Side view > Rear Side B C C C Front Side A Front Side A Rear Side B C C Front Side A < Top view > Rear Side Front Side B C A A 250mm(9-13/16 inch) or more (350mm(13-3/4 inch)or more at the coastal area.) B 150mm(5-7/8 inch) from the wall A CAUTION Wall height(H) must not exceed height of the product. If the wall height is higher than the whole height of product by (h), Add (h) to , . < Side view > Rear Side A B B B Front Side < Top view > Rear Side B Rear Side A B Front Side A B Front Side Installation Manual 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91

Installation Manual
13
Installation Space
ENGLISH
Installation Space
Individual Installation
Basic space required
A space of at least 250mm(9-13/16 inch) is necessary at the back for inlet air. Taking servicing, etc. from the
rear into account, a space of about 915mm(36 inches) should be provided, the same as at the front.
B
A
Control Box
Front Side
Rear Side
B
A
Control Box
Front Side
Rear Side
B
A
Control Box
Front Side
Rear Side
C
A
B
C
A
B
h
H
Front Side
Rear Side
C
A
B
C
Front Side
Rear Side
C
A
B
C
Front Side
Rear Side
< Side view >
< Top view >
< Side view >
< Top view >
C
E
D
B
A
B
A
h
H
Front Side
Rear Side
B
A
B
Front Side
Rear Side
B
A
B
Front Side
Rear Side
< Side view >
< Top view >
915mm(36 inches) or more (Control box is open/close type)
250mm(9-13/16 inch)
or more
Top discharge (open in principle)
Front inlet (open in principle)
Rear inlet (open in principle)
A
B
C
D
E
A
B
C
915mm(36 inches) or more
(Control box is open/close type)
250mm(9-13/16 inch) or more
150mm(5-7/8 inch) from the wall
A
B
250mm(9-13/16 inch) or more
(350mm(13-3/4 inch)or more at the coastal area.)
150mm(5-7/8 inch) from the wall
CAUTION
Wall height(H) must not exceed height
of the product. If the wall height is
higher than the whole height of prod-
uct by (h), Add (h) to
,
.
CAUTION
Wall height(H) must not exceed
height of the product. If the wall
height is higher than the whole
height of product by (h), Add (h) to
,
.
When inlet air enters from right and left sides of unit