Makita RJ01W Technical Reference - Page 12

Switch trigger side, Housing L, Housing R side, Terminal

Page 12 highlights

Wiring diagram (cont.) Fig. D-3 Wiring to DC Motor Assemble DC Motor to Housing (L), * the Lead wires must be faced to Housing (R) side. * the Lead wire (black) must be located to the Switch trigger side. P 12/ 12 Fig. D-4 Wiring to Terminal Connect the Lead wires to Terminal as drawn below. Housing L side 30 degrees Red point mark Housing R side Terminal Switch trigger side Bend the Terminal with black Lead wire 30 degrees toward the center so that the Terminal does not touch the rib for setting DC Motor. Now, Switch can be mounted to Housing (L) as drawn in Fig. D-5. Fig. D-5 Wiring of Lead wires of DC Motor, Switch, Terminal in Housing (L) Pass the Lead wires (black, red) between DC motor and Switch through Line filter when it is used. And put the Line filter to this place. Housing (L) Line filter location when it is used. Bend Terminal of DC motor inside so as to be stored between Rib C and Rib D. Rib C Route Lead wires (white, black) from connector to this place and store them in this place. DC Motor Switch Rib D Switch trigger Store Switch lead wire (red) to Terminal within the Terminal's width designated with dotted lines. Lead wire (red)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Switch
Switch
trigger
Switch trigger side
Now, Switch can be mounted to Housing (L) as drawn in
Fig. D-5
.
Line filter location
when it is used.
Store Switch lead wire (red) to Terminal
within the Terminal’s width designated
with dotted lines.
Housing (L)
Pass the Lead wires (black, red) between
DC motor and Switch through Line filter
when it is used.
And put the Line filter to this place.
Fig. D-5
Wiring of Lead wires of
DC Motor, Switch, Terminal in Housing (L)
Route Lead wires (white, black) from
connector to this place and store them
in this place.
DC Motor
Fig. D-3
Fig. D-4
Wiring to DC Motor
Wiring to Terminal
Assemble DC Motor to Housing (L),
* the Lead wires must be faced to Housing (R) side.
* the Lead wire (black) must be located to the Switch trigger side.
Connect the Lead wires
to
Terminal as drawn below.
Red point mark
Housing L
side
Housing R side
Bend the Terminal with black Lead wire 30 degrees toward the center
so that the Terminal does not touch the rib for setting DC Motor.
Terminal
30 degrees
Lead wire (red)
Rib C
Rib D
Bend Terminal of DC motor inside
so as to be stored between Rib C
and Rib D.
W
iring diagram (cont.)
P 1
2
/ 1
2