Front Panel LEDs on the I-1400, Management Port Speed

Page 11 highlights

McAfee® IntruShield® IPS 4.1 IntruShield Sensor 1400 Product Guide An introduction to IntruShield sensors The IntruShield 1400 Sensor 8 Built-in internal tap (not shown). The internal tap (used with the 10/100 ports) provide stealth mode monitoring functionality and forgo the need of an external tap or connection to a SPAN port or hub. When the 10/100 ports are configured to monitor a network segment in peer mode, their internal tap allows a network segment to be connected directly to the sensor: one port receives/transmits from Device A (For example, a firewall, router, switch) and the other receives/transmits from Device B. You can also change 'on the fly' from internal tap mode to in-line mode. Note: Internal taps fail open, meaning that should the sensor fail physically while running in internal tap mode, the connection is not disrupted; your network traffic will continue to flow unimpeded (although there may be a minor disruption as the network devices surrounding the sensor establish direct connectivity). If you want to have fail-closed functionality, you can accomplish this via cabling. Normal Cat 5/Cat 5e cabling will fail open. Special cabling using the supplied failclosed dongles provides fail-closed functionality. For more information, see the section, Cabling the Monitoring ports (on page 15). Front Panel LEDs on the I-1400 The front panel LEDs provide status information for the health of the sensor and the activity on its ports. The following table describes the I-1400 front panel LEDs. LED Power Up Boot Status Green Off Green Off Amber Off Management Port Speed Management Port Link Fan Amber Off Green Off Green Amber Description The sensor is powered on and functioning. The sensor is powered off. The sensor is up and initialized. The sensor is powered off or is rebooting. The sensor is in the process of booting up. The sensor is powered off or the sensor is working fine after bootup initialization. The port speed is 100 Mbps The port speed is 10 Mbps The link is connected. The link is disconnected. Fans operating. One or more of the fans has failed. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

McAfee® IntruShield® IPS 4.1
An introduction to IntruShield sensors
IntruShield Sensor 1400 Product Guide
The IntruShield 1400 Sensor
8
Built-in internal tap (not shown)
. The internal tap (used with the 10/100 ports) provide
stealth mode monitoring functionality and forgo the need of an external tap or
connection to a SPAN port or hub. When the 10/100 ports are configured to
monitor a network segment in peer mode, their internal tap allows a network
segment to be connected directly to the sensor: one port receives/transmits from
Device A (For example, a firewall, router, switch) and the other
receives/transmits from Device B. You can also change ‘on the fly’ from internal
tap mode to in-line mode.
Note:
Internal taps
fail open
, meaning that should the sensor fail physically while
running in internal tap mode, the connection is not disrupted; your network traffic
will continue to flow unimpeded (although there may be a minor disruption as the
network devices surrounding the sensor establish direct connectivity).
If you want to have fail-closed functionality, you can accomplish this via cabling.
Normal Cat 5/Cat 5e cabling will fail open. Special cabling using the supplied fail-
closed dongles provides fail-closed functionality. For more information, see the
section, Cabling the Monitoring ports (on page 15).
Front Panel LEDs on the I-1400
The front panel LEDs provide status information for the health of the sensor and the
activity on its ports. The following table describes the I-1400 front panel LEDs.
LED
Status
Description
Power
Green
Off
The sensor is powered on and
functioning.
The sensor is powered off.
Up
Green
Off
The sensor is up and initialized.
The sensor is powered off or is
rebooting.
Boot
Amber
Off
The sensor is in the process of booting
up.
The sensor is powered off or the
sensor is working fine after bootup
initialization.
Management Port Speed
Amber
Off
The port speed is 100 Mbps
The port speed is 10 Mbps
Management Port Link
Green
Off
The link is connected.
The link is disconnected.
Fan
Green
Amber
Fans operating.
One or more of the fans has failed.
3