McAfee® IntruShield® IPS 4.1 IntruShield Sensor 1400 Product Guide Before you install Sensor capacity for I-1400 sensor Sensor Specifications Description Relative Humidity (Non- Operating condensing) 10%-90% non-condensing Non-operating 5% to 95% non-condensing System Heat Dissipation 341 BTU/hr Airflow Altitude Throughput 200 lfm (1 m/s) Sea level to 10,000 ft (3050 m) 200 Mbps Cabling Specifications: Note the following cabling specifications for the sensor: • Category 5 Enhanced (Cat 5e) cable is required for transmission speeds up to 1 Gigabit per second (Gigabit Ethernet). • For Ethernet networks running at 10 or 100 Mbps, Category 5 (Cat 5) OR Cat 5e cable can be used. Note: Throughout this guide, cabling specifications will be mentioned as Cat5/Cat5e. Sensor capacity for I-1400 sensor The following table lists the sensor limitations by category: Maximum Type I-1400 Concurrent connections Connections established per sec. Concurrent SSL Flows (2.1.x and later) Number of SSL keys that can be stored on the sensor 80,000 2,000 NA NA Virtual Interfaces (VIDS) 32 VLANS / CIDR Blocks 64 VLANS / CIDR Blocks per Physical Port Customized attacks Alert filters Default number of supported UDP Flows Supported UDP Flows 64 40,000 32,000 6,000 60,000 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

McAfee® IntruShield® IPS 4.1
Before you install
IntruShield Sensor 1400 Product Guide
Sensor capacity for I-1400 sensor
Sensor Specifications
Description
Relative Humidity (Non-
condensing)
Operating
10%-90% non-condensing
Non-operating
5% to 95% non-condensing
System Heat Dissipation
341 BTU/hr
Airflow
200 lfm (1 m/s)
Altitude
Sea level to 10,000 ft (3050 m)
Throughput
200 Mbps
Cabling Specifications:
Note the following cabling specifications for the sensor:
Category 5 Enhanced (Cat 5e) cable is required for transmission speeds up
to 1 Gigabit per second (Gigabit Ethernet).
For Ethernet networks running at 10 or 100 Mbps, Category 5 (Cat 5) OR
Cat 5e cable can be used.
Note:
Throughout this guide, cabling specifications will be mentioned as
Cat5/Cat5e.
Sensor capacity for I-1400 sensor
The following table lists the sensor limitations by category:
Maximum Type
I-1400
Concurrent connections
80,000
Connections established per sec.
2,000
Concurrent SSL Flows (2.1.x and later)
NA
Number of SSL keys that can be stored on the sensor
NA
Virtual Interfaces (VIDS)
32
VLANS / CIDR Blocks
64
VLANS / CIDR Blocks per Physical Port
64
Customized attacks
40,000
Alert filters
32,000
Default number of supported UDP Flows
6,000
Supported UDP Flows
60,000