Appendix B Cabling Specifications This appendix provides specifications for cables used with the NETGEAR Model EN516 Ethernet Hub. Cable Specifications For 10 Mbps connections, Category 3, 4, or 5 cables can be used. NETGEAR highly recommends using Category 5 cable to avoid unnecessary expense or confusion if you upgrade to Fast Ethernet. Table B-1 lists the electrical requirements of Category 3, 4, and 5 cables. Table B-1. Electrical requirements of Category 3, 4, and 5 cables Specification Number of pairs Impedance Mutual capacitance at 1 KHz Maximum attenuation (dB per 100 m, at 20° C) Category 3 Four 100 Ω ± 15% ≤6.6 nF per 100 m at 4 MHz: 5.6 at 10 MHz: 9.8 at 16 MHz: 13.1 Category 4 Four 100 Ω ± 15% ≤5.6 nF per 100 m at 4 MHz: 4.3 at 10 MHz: 7.2 at 16 MHz: 8.9 Category 5 Four 100 Ω ± 15% ≤5.6 nF per 100 m at 16 MHz: 8.2 at 31 MHz: 11.7 at 100 MHz: 22 NEXT loss (dB minimum) at 4 MHz: 32 at 10 MHz: 26 at 16 MHz: 23 at 4 MHz: 47 at 10 MHz: 41 at 16 MHz: 38 at 16 MHz: 44 at 31 MHz: 39 at 100 MHz: 32 Cabling Specifications B-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

Cabling Specifications
B-1
Appendix B
Cabling Specifications
This appendix provides specifications for cables used with the NETGEAR Model EN516 Ethernet
Hub.
Cable Specifications
For 10 Mbps connections, Category 3, 4, or 5 cables can be used. NETGEAR highly recommends
using Category 5 cable to avoid unnecessary expense or confusion if you upgrade to Fast Ethernet.
Table B-1 lists the electrical requirements of Category 3, 4, and 5 cables.
Table B-1.
Electrical requirements of Category 3, 4, and 5 cables
Specification
Category 3
Category 4
Category 5
Number of pairs
Four
Four
Four
Impedance
100
±
15%
100
±
15%
100
±
15%
Mutual capacitance
at 1 KHz
6.6 nF per 100 m
5.6 nF per 100 m
5.6 nF per 100 m
Maximum attenuation
(dB per 100 m, at 20
°
C)
at 4 MHz: 5.6
at 10 MHz: 9.8
at 16 MHz: 13.1
at 4 MHz: 4.3
at 10 MHz: 7.2
at 16 MHz: 8.9
at 16 MHz: 8.2
at 31 MHz: 11.7
at 100 MHz: 22
NEXT loss
(dB minimum)
at 4 MHz: 32
at 10 MHz: 26
at 16 MHz: 23
at 4 MHz: 47
at 10 MHz: 41
at 16 MHz: 38
at 16 MHz: 44
at 31 MHz: 39
at 100 MHz: 32