Netgear GS748TP-100NAS GS724TP User Manual - Page 54

View Content

Page 54 highlights

GS700TP Smart Switch Software Administration Manual 3. Click Delete to remove the entry. View Content SNMP views provide or block access to device features or portions of features. For example, a view can be defined to provide a view that SNMP group A has Read Only (R/O) access to Multicast groups, while SNMP group B has Read-Write (R/W) access to Multicast groups. Feature access is granted via the MIB name or MIB Object ID. To define the SNMP View Content: 1. Click System > SNMP > SNMPv3 > View Content. The SNMPv3 View Content screen displays: Figure 3-13 The SNMPv3 View Content screen contains the following fields: Views • View Name - Select the user-defined view name. The view name can contain a maximum of 30 alphanumeric characters. • Object ID Subtree - Enter the device feature OID. • View Type - Select whether the defined OID branch will be included in or excluded from the selected SNMP view. The possible field values are: - Included - The OID is included in the SNMP view. - Excluded - The OID is excluded from the SNMP view. 2. Select the View Name from the list in the provided field in the Views table. 3. Enter the Object ID Subtree in the provided field in the first row. 3-20 v1.0, December 2007 Managing System Settings

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

GS700TP Smart Switch Software Administration Manual
3-20
Managing System Settings
v1.0, December 2007
3.
Click
Delete
to remove the entry.
View Content
SNMP views provide or block access to device features or portions of features. For example, a
view can be defined to provide a view that SNMP group A has Read Only (R/O) access to
Multicast groups, while SNMP group B has Read-Write (R/W) access to Multicast groups. Feature
access is granted via the MIB name or MIB Object ID.
To define the SNMP View Content:
1.
Click
System
>
SNMP > SNMPv3 > View Content
. The SNMPv3 View Content screen
displays:
The SNMPv3 View Content screen contains the following fields:
Views
View Name
– Select the user-defined view name. The view name can contain a maximum
of 30 alphanumeric characters.
Object ID Subtree
– Enter the device feature OID.
View Type
– Select whether the defined OID branch will be included in or excluded from
the selected SNMP view. The possible field values are:
Included – The OID is included in the SNMP view.
Excluded – The OID is excluded from the SNMP view.
2.
Select the
View Name
from the list in the provided field in the Views table.
3.
Enter the
Object ID Subtree
in the provided field in the first row.
Figure 3-13