NordicTrack 14.0 Elliptical Uk Manual - Page 35

Maintenance And Troubleshooting

Page 35 highlights

MAINTENANCE AND TROUBLESHOOTING IMPORTANT: Servicing other than the procedures described below should be performed only by an authorized service representative. Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. To clean the elliptical, first press the power switch to the off position and unplug the power cord. Wipe exterior parts of the elliptical with a damp cloth and a few drops of mild dish soap. Then, wipe the elliptical with a cloth dampened with clean water, and dry the elliptical with a soft towel. IMPORTANT: Do not spray liquid directly onto the console or onto other parts of the elliptical. To avoid damage to the console, keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING If the console does not display your heart rate when you hold the handgrip heart rate monitor, or if the displayed heart rate appears to be too high or too low, see step 5 on page 25. Next, see EXPLODED DRAWING A on page 41 and EXPLODED DRAWING B on page 42. Remove the M8 x 16mm Screw (72), the Axle Cover (53), and the M8 x 25mm Washer (149) from the upper end of the Right Roller Arm (45). Then, remove the Right Roller Arm from the right Crank Arm (20). Set the Right Roller Arm out of the way. Then, see assembly step 22 on page 15. Using a flat screwdriver, release the tabs on the Shield Cover (75) and slide it upward. See EXPLODED DRAWING C on page 43. Remove all the M4 x 16mm Screws (104) from the Right Front Shield (74). Next, remove the M4 x 22mm Screw (127) from the Left Front Shield (73). Then, gently remove the Right Front Shield. Locate and loosen the Idler Screw (101). Next, tighten the Belt Adjustment Screw (88) until the Drive Belt (113) is tight. Then, retighten the Idler Screw. If the console does not display your heart rate when you use the chest heart rate monitor, see TROUBLESHOOTING on page 17. HOW TO ADJUST THE DRIVE BELT 113 If the pedals slip while you are pedaling, even while the resistance is adjusted to the highest level, the drive belt may need to be adjusted. 101 Press the power switch to the off position and unplug the power cord. 88 To adjust the drive belt, first see assembly step 11 on page 10. Remove the Right Roller Arm (45) from the Right Pedal Arm (58). Reattach the right front shield, the shield cover, and the right roller arm. 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

35
IMPORTANT: Servicing other than the procedures
described below should be performed only by an
authorized service representative.
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical,
first press the power switch
to the off position and unplug the power cord.
Wipe exterior parts of the elliptical with a damp cloth
and a few drops of mild dish soap. Then, wipe the
elliptical with a cloth dampened with clean water, and
dry the elliptical with a soft towel.
IMPORTANT: Do
not spray liquid directly onto the console or onto
other parts of the elliptical.
To avoid damage to the
console, keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the
displayed heart rate appears to be too high or too low,
see step 5 on page 25.
If the console does not display your heart rate
when you use the chest heart rate monitor, see
TROUBLESHOOTING on page 17.
HOW TO ADJUST THE DRIVE BELT
If the pedals slip while you are pedaling, even while
the resistance is adjusted to the highest level, the drive
belt may need to be adjusted.
Press the power switch to the off position and
unplug the power cord.
To adjust the drive belt, first see assembly step 11 on
page 10. Remove the Right Roller Arm (45) from the
Right Pedal Arm (58).
Next, see EXPLODED DRAWING A on page 41 and
EXPLODED DRAWING B on page 42. Remove the
M8 x 16mm Screw (72), the Axle Cover (53), and the
M8 x 25mm Washer (149) from the upper end of the
Right Roller Arm (45). Then, remove the Right Roller
Arm from the right Crank Arm (20). Set the Right Roller
Arm out of the way.
Then, see assembly step 22 on page 15. Using a flat
screwdriver, release the tabs on the Shield Cover (75)
and slide it upward.
See EXPLODED DRAWING C on page 43. Remove
all the M4 x 16mm Screws (104) from the Right Front
Shield (74). Next, remove the M4 x 22mm Screw (127)
from the Left Front Shield (73).
Then, gently remove
the Right Front Shield.
Locate and loosen the Idler Screw (101). Next, tighten
the Belt Adjustment Screw (88) until the Drive Belt
(113) is tight. Then, retighten the Idler Screw.
Reattach the right front shield, the shield cover, and the
right roller arm.
MAINTENANCE AND TROUBLESHOOTING
101
88
113