Panasonic TH-65PF12EK User Manual - Page 53

Adjustments

Page 53 highlights

Options Adjustments Item INPUT lock Adjustments Off PC INPUT1 INPUT2 INPUT3 Locks the input switch operation. Notes: • Only the adjusted signal is displayed (see page 14). • Signal can be displayed when the Terminal board is installed. • Input switch can be used when this is set to "Off". • In two screen display mode, if anything other than "Off" is set, the value will be fixed as the value input in the single screen display mode. • When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) Off MENU&ENTER On Off: All the buttons on main unit can be used. Button lock Remocon User level MENU&ENTER: Locks and buttons on main unit. MENU ENTER/ On: Locks all the button on main unit. Sets Button lock with the unit buttons in the following procedure. Off: Press four times→Press four times→Press four times→Press MENU&ENTER: Press INPUT ENTER/ four times→Press four times→Press four times→Press ENTER/ INPUT ENTER/ On: Press four times→Press four times→Press four times→Press ENTER/ ENTER/ Off User1 User2 User3 Off: You can use all of the buttons on the remote control. User1: You can only use , , , , buttons on the remote control. User2: You can only use button on the remote control. User3:Locks all the buttons on remote control. Off-timer function Enable: Enables the "Off-timer function". Disable:Disables the "Off-timer function". Note: When "Disable" is set, the Off-timer is cancelled. Initial Power Mode ID select Remote ID Serial ID Normal Standby On Sets the power mode of the unit for when the power recovers from failure or after plugging off and in again. Normal: Power returns in as the same state as before the power interruption. Standby:Power returns in standby mode. (Power Indicator : red/orange) On: Power returns in power On. (Power Indicator : green) Note: When using multiple displays, "Standby" is preferred to be set in order to reduce a power load. Sets panel ID number when panel is used in "Remote ID" or "Serial ID". Set value range: 0 - 100 (Standard value: 0) The setting of this menu is valid only when using ID remote control. Off: Disables ID remote control functions. You can use normal remote control operations. On: Enable ID remote control functions. Note: To use the ID remote control function, it is necessary to set each ID number of remote control and display unit. About the setting method, please refer to "ID Remote Control Function" (see page 42) and "ID select" (above-mentioned). Sets the panel ID Control. Off: Disables external control by the ID. On: Enables the external control by the ID. Adjusts the image display size on screen. Off: Sets the normal image display size on screen. On: Sets the image display size approximately 95 % of the normal image display. Off On Display size Notes: • This setting is valid only when the input signals are as follows; NTSC, PAL, SECAM, M.NTSC, PAL60, PAL-M, PAL-N (BNC Dual Video Terminal Board (TY-FB9BD)) 525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p, 1125/60p, 1125/50p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI) • This setting is invalid when two screen display, digital zoom, Multi display or Portrait display is selected. • When "Display size" is set to "On", "H-Pos" and "V-Pos" in "Pos. /Size" can be adjusted. • Refer to each board's operating instruction for DVI, SDI, HDMI's corresponding signals. 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

53
Options Adjustments
Item
Adjustments
INPUT lock
Off
PC
INPUT1
INPUT2
INPUT3
Locks the input switch operation.
Notes:
• Only the adjusted signal is displayed (see page 14).
• Signal can be displayed when the Terminal board is installed.
• Input switch can be used when this is set to “Off”.
• In two screen display mode, if anything other than “Off” is set, the value will be
xed as the value input
in the single screen display mode.
• When a dual input terminal board is attached, A or B is displayed depending on the selected input signal.
(Ex. INPUT1A, INPUT1B)
Button lock
Off
MENU&ENTER
On
Off:
All the buttons on main unit can be used.
MENU&ENTER:
Locks
MENU
and
ENTER/
buttons on main unit.
On:
Locks all the button on main unit.
Sets Button lock with the unit buttons in the following procedure.
Off:
Press
four times
Press
INPUT
four times
Press
four times
Press
ENTER/
MENU&ENTER:
Press
ENTER/
four times
Press
four times
Press
INPUT
four times
Press
ENTER/
On:
Press
four times
Press
ENTER/
four times
Press
four times
Press
ENTER/
Remocon User level
Off
User1
User2
User3
Off:
You can use all of the buttons on the remote control.
User1
: You can only use
,
,
,
,
buttons on the remote control.
User2
: You can only use
button on the remote control.
User3:
Locks all the buttons on remote control.
Off-timer function
Enable:
Enables the “Off-timer function”.
Disable:
Disables the “Off-timer function”.
Note:
When “Disable” is set, the Off-timer is cancelled.
Initial Power Mode
Normal
Standby
On
Sets the power mode of the unit for when the power recovers from failure or after plugging off and in again.
Normal:
Power returns in as the same state as before the power interruption.
Standby
:
Power returns in standby mode. (Power Indicator : red/orange)
On:
Power returns in power On. (Power Indicator : green)
Note:
When using multiple displays, “Standby” is preferred to be set in order to reduce a power load.
ID select
Sets panel ID number when panel is used in “Remote ID” or “Serial ID”.
Set value range: 0 - 100
(Standard value: 0)
Remote ID
The setting of this menu is valid only when using ID remote control.
Off:
Disables ID remote control functions. You can use normal remote control operations.
On:
Enable ID remote control functions.
Note:
To use the ID remote control function, it is necessary to set each ID number of remote control and display unit.
About the setting method, please refer to “ID Remote Control Function” (see page 42) and “ID
select” (above-mentioned).
Serial ID
Sets the panel ID Control.
Off:
Disables external control by the ID.
On:
Enables the external control by the ID.
Display size
Adjusts the image display size on screen.
Off:
Sets the normal image display size on screen.
On:
Sets the image display size approximately 95 % of the normal image display.
Off
On
Notes:
• This setting is valid only when the input signals are as follows;
NTSC, PAL, SECAM, M.NTSC, PAL60, PAL-M, PAL-N (BNC Dual Video Terminal Board (TY-FB9BD))
525i,
525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p,
1125/60p, 1125/50p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI)
• This setting is invalid when two screen display, digital zoom, Multi display or Portrait display is
selected.
• When “Display size” is set to “On”, “H-Pos” and “V-Pos” in “Pos. /Size” can be adjusted.
• Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals.