Sanyo WXU300 Instruction Manuals, PLC-WXU300 - Page 79
Configurations of Terminals
UPC - 086483074226
View all Sanyo WXU300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Appendix Configurations of Terminals COMPUTER IN 1 /COMPONENT IN /COMPUTER IN 2/MONITOR OUT (ANALOG) Terminal: Analog RGB (Mini D-sub 15 pin) 54 32 1 10 9 8 7 6 15 14 13 12 11 1 Red (R/Cr) Input/Output 2 Green (G/Y) Input/Output 3 Blue (B/Cb) Input/Output 4 ----- 5 Ground (Horiz.sync.) 6 Ground (Red) 7 Ground (Green) 8 Ground (Blue) 9 +5V Power/----10 Ground (Vert.sync.) 11 Ground/----12 DDC Data/----13 Horiz. sync. Input/Output (Composite H/V sync.) 14 Vert. sync. 15 DDC Clock/----- CONTROL PORT CONNECTOR (D-sub 9 pin) Serial 1 ----2 RXD 3 TXD 4 ----5 SG 6 ----7 RTS 8 CTS 9 ----- LAN TERMINAL 87654321 1 TX + 5 ----- 2 TX - 6 RX - 3 RX + 7 ----- 4 ----- 8 ----- HDMI (19 PIN Type A) 1 3 5 7 9 11 13 15 17 19 2 4 6 8 10 12 14 16 18 1 TMDS Data 2+ Input 11 Ground (TMDS Clock) 2 Ground (TMDS Data 2) 12 TMDS Clock- Input 3 TMDS Data 2- Input 13 ----- 4 TMDS Data 1+ Input 14 ----- 5 Ground (TMDS Data 1) 15 SCL 6 TMDS Data 1- Input 16 SDA 7 TMDS Data 0+ Input 17 Ground (DDC/CEC) 8 Ground (TMDS Data 0) 18 +5V Power 9 TMDS Data 0- Input 19 Plug insert detection 10 TMDS Clock+ Input 79