Sony BVME250 User Manual - Page 59

P&P Setting, White], Green, Yellow, Magenta, Black, Auto], Pixel Zoom Setting, Gamut Error Display

Page 59 highlights

Chapter 3 Menu P&P Setting Menu Line Color Line Bright Wipe Line Display Line Color Line Bright Position Butterfly Line Display Line Color Line Bright Position Blending Blending Ratio Pixel Zoom Setting Line Color Gamut Error Display Gamut Error Display Function and operation ([ ]: factory setting) Sets the boundary line color of two pictures. You can select from [White] (white), Red (red), Green (green), Blue (blue), Yellow (yellow), Cyan (cyan), Magenta (magenta) or Black (black). Sets the luminance of the boundary line. You can select from High (bright) or [Low] (dark). Sets the wipe display. Sets display mode of the boundary line. [Auto]: Appears when the position of the boundary line is set and disappears after a while. On: Always displayed. Off: Not displayed. Sets the boundary line color. You can select from [White] (white), Red (red), Green (green), Blue (blue), Yellow (yellow), Cyan (cyan) or Magenta (magenta) or Black (black). Sets the luminance of the boundary line. You can select from High (bright) or [Low] (dark). Sets the position of the boundary line. Set to -100 (leftward) to +100 (rightward). [000] Sets the butterfly display. Sets display mode of the boundary line. Off: Not displayed. [On]: Always displayed. Sets the boundary line color. You can select from [White] (white), Red (red), Green (green), Blue (blue), Yellow (yellow), Cyan (cyan) or Magenta (magenta) or Black (black). Sets the luminance of the boundary line. You can select from High (bright) or [Low] (dark). Sets the position of the boundary line. Set to -100 to +100. [000] Sets the blending display. Sets the blending ratio when two images are mixed. Set to 000 (Signal A disappears.) to 100% (Signal B disappears). [050] Sets the pixel zoom. Sets the boundary line color. You can select from [White] (white), Red (red), Green (green), Blue (blue), Yellow (yellow), Cyan (cyan) or Magenta (magenta) or Black (black). Sets the gamut error display. A zebra pattern is superimposed on the portion where an error is detected. Notes • The gamut error display function is effective when the input signal is 3G/HD/SD SDI, HDMI, or DisplayPort (and the quantization range for the signal is Limit). It is effective regardless of the signal format, when Gamma is set to S-LOG Standard or S-LOG Full in the Color Profile menu. • The gamut error display function does not work in the following cases: - When the input signal has no sync signal - When the internal signal is displayed - When H Delay/V Delay is set to On - When Side by Side, Wipe, Butterfly or Blending is set to On • In under scan mode, each one line of the upper and lower lines of the video signal is also detected for gamut error display. • The time code display, the closed caption display when the BKM-244CC is installed, and the embedded audio level display when the BKM-250TG is installed are also detected for gamut error display. • In over scan mode, 5% mask portion is also detected for gamut error display. However, the zebra pattern is not displayed on 5% mask portion. Sets whether or not to display the gamut error ([Off] or On). 59 Function Setting Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136

59
Function Setting Menu
Chapter 3
Menu
P&P Setting
Line Color
Sets the boundary line color of two pictures.
You can select from
[White]
(white),
Red
(red),
Green
(green),
Blue
(blue),
Yellow
(yellow),
Cyan
(cyan),
Magenta
(magenta) or
Black
(black).
Line Bright
Sets the luminance of the boundary line.
You can select from
High
(bright) or
[Low]
(dark).
Wipe
Sets the wipe display.
Line Display
Sets display mode of the boundary line.
[Auto]:
Appears when the position of the boundary line is set and disappears after a
while.
On:
Always displayed.
Off:
Not displayed.
Line Color
Sets the boundary line color.
You can select from
[White]
(white),
Red
(red),
Green
(green),
Blue
(blue),
Yellow
(yellow),
Cyan
(cyan) or
Magenta
(magenta) or
Black
(black).
Line Bright
Sets the luminance of the boundary line.
You can select from
High
(bright) or
[Low]
(dark).
Position
Sets the position of the boundary line.
Set to
–100
(leftward) to
+100
(rightward).
[000]
Butterfly
Sets the butterfly display.
Line Display
Sets display mode of the boundary line.
Off:
Not displayed.
[On]:
Always displayed.
Line Color
Sets the boundary line color.
You can select from
[White]
(white),
Red
(red),
Green
(green),
Blue
(blue),
Yellow
(yellow),
Cyan
(cyan) or
Magenta
(magenta) or
Black
(black).
Line Bright
Sets the luminance of the boundary line.
You can select from
High
(bright) or
[Low]
(dark).
Position
Sets the position of the boundary line.
Set to
–100
to
+100
.
[000]
Blending
Sets the blending display.
Blending Ratio
Sets the blending ratio when two images are mixed.
Set to
000
(Signal A disappears.) to
100
% (Signal B disappears).
[050]
Pixel Zoom Setting
Sets the pixel zoom.
Line Color
Sets the boundary line color.
You can select from
[White]
(white),
Red
(red),
Green
(green),
Blue
(blue),
Yellow
(yellow),
Cyan
(cyan) or
Magenta
(magenta) or
Black
(black).
Gamut Error Display
Sets the gamut error display.
A zebra pattern is superimposed on the portion where an error is detected.
Notes
The gamut error display function is effective when the input signal is 3G/HD/SD SDI, HDMI,
or DisplayPort (and the quantization range for the signal is Limit). It is effective regardless
of the signal format, when Gamma is set to S-LOG Standard or S-LOG Full in the Color
Profile menu.
The gamut error display function does not work in the following cases:
- When the input signal has no sync signal
- When the internal signal is displayed
- When H Delay/V Delay is set to On
- When Side by Side, Wipe, Butterfly or Blending is set to On
In under scan mode, each one line of the upper and lower lines of the video signal is also
detected for gamut error display.
The time code display, the closed caption display when the BKM-244CC is installed, and
the embedded audio level display when the BKM-250TG is installed are also detected for
gamut error display.
In over scan mode, 5% mask portion is also detected for gamut error display.
However, the
zebra pattern is not displayed on 5% mask portion.
Gamut Error Display
Sets whether or not to display the gamut error (
[Off]
or
On
).
Menu
Function and operation ([