Sony HT-SS2000 Operating Instructions - Page 28

When error codes appear, To rectify the error, When you select WARN CHK, Press, repeatedly to select

Page 28 highlights

2 Press V/v repeatedly to select the item. Then, press . Item Explanation RETRY Performs the Auto Calibration again. SAVE Saves the measurement results and exits the setting process. WARN CHK Displays warning concerning the measurement results. See "When you select "WARN CHK"" (page 28). PHASE Displays the phase of each speaker (in phase/out of phase). See "When you select "PHASE"" (page 29). DISTANCE Displays the measurement result for speaker distance. LEVEL Displays the measurement result for speaker level. EXIT Exits the setting process without saving the measurement results. 3 Save the measurement result. Select "SAVE" in step 2. The measurement results are saved. When error codes appear Try the remedies and perform the Auto Calibration again. Error code Cause and remedies ERROR 32 ERROR F 33 None of the speakers were detected. Make sure that the optimizer microphone is connected properly and perform the Auto Calibration again. If the optimizer microphone is connected properly but the error code appears, the optimizer microphone cable may be damaged or improperly connected. • None of the front speakers are connected or only one front speaker is connected. • The optimizer microphone is not connected. Error code Cause and remedies ERROR SR 33 Either the left or right surround speakers is not connected. ERROR SW 33 Sub woofer is not connected. Connect the sub woofer to the SUBWOOFER terminal. ERROR 33 Wrong speaker detection due to noise. Make sure the environment is quiet during Auto Calibration. To rectify the error 1 Record down the error code. 2 Press , "RETRY Y" appears on the display. 3 Rectify the error. For details, see "When error codes appear" above. 4 Press to perform Auto Calibration again. When you select "WARN CHK" If a warning on the measurement result is present, detailed information is displayed. Press to return to step 2 of "Confirming/saving the measurement results". Warning code Explanation WARN 40 The Auto Calibration has completed. However, the noise level is high. You may be able to perform the Auto Calibration properly if you try it again, even though the measurement cannot be performed in all environments. Try to perform the Auto Calibration in a quiet environment. WARN 41 The sound input from the optimizer microphone is out of the acceptable range. It is louder than the loudest sound that can be measured. Try to perform the Auto Calibration when the environment is quiet enough to allow proper measurement. WARN 42 The volume of the receiver is out of the acceptable range. Try to perform the Auto Calibration when the environment is quiet enough to allow proper measurement. 28GB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

28
GB
2
Press
V
/
v
repeatedly to select
the item. Then, press
.
3
Save the measurement result.
Select “SAVE” in step 2.
The measurement results are saved.
When error codes appear
Try the remedies and perform the Auto
Calibration again.
To rectify the error
1
Record down the error code.
2
Press
, “RETRY Y” appears on the display.
3
Rectify the error.
For details, see “When error codes appear”
above.
4
Press
to perform Auto Calibration again.
When you select “WARN CHK”
If a warning on the measurement result is
present, detailed information is displayed.
Press
to return to step 2 of
“Confirming/saving the
measurement results”.
Item
Explanation
RETRY
Performs the Auto
Calibration again.
SAVE
Saves the measurement
results and exits the setting
process.
WARN CHK
Displays warning
concerning the
measurement results. See
“When you select “WARN
CHK”” (page 28).
PHASE
Displays the phase of each
speaker (in phase/out of
phase). See “When you
select “PHASE”” (page 29).
DISTANCE
Displays the measurement
result for speaker distance.
LEVEL
Displays the measurement
result for speaker level.
EXIT
Exits the setting process
without saving the
measurement results.
Error code
Cause and remedies
ERROR 32
None of the speakers were
detected. Make sure that the
optimizer microphone is
connected properly and perform
the Auto Calibration again.
If the optimizer microphone is
connected properly but the error
code appears, the optimizer
microphone cable may be
damaged or improperly connected.
ERROR F 33
None of the front speakers are
connected or only one front
speaker is connected.
The optimizer microphone is not
connected.
ERROR SR 33
Either the left or right surround
speakers is not connected.
ERROR SW 33
Sub woofer is not connected.
Connect the sub woofer to the
SUBWOOFER terminal.
ERROR 33
Wrong speaker detection due to
noise. Make sure the environment
is quiet during Auto Calibration.
Warning code
Explanation
WARN 40
The Auto Calibration has
completed. However, the noise
level is high. You may be able to
perform the Auto Calibration
properly if you try it again, even
though the measurement cannot be
performed in all environments. Try
to perform the Auto Calibration in a
quiet environment.
WARN 41
The sound input from the
optimizer microphone is out of
the acceptable range. It is louder
than the loudest sound that can be
measured. Try to perform the
Auto Calibration when the
environment is quiet enough to
allow proper measurement.
WARN 42
The volume of the receiver is out
of the acceptable range. Try to
perform the Auto Calibration
when the environment is quiet
enough to allow proper
measurement.
Error code
Cause and remedies