Thermador UCVM30FS Installation Instructions - Page 13

Step 7: Mount Integral Blower or, Outlet Duct Transition for Remote or, Inline Blower

Page 13 highlights

Step 7: Mount Integral Blower or Outlet Duct Transition for Remote or Inline Blower Integral Blower (see Figures 9 and 11 for further detail): Y A. Attach blower in front of round exhaust outlet with 4-6 (depending on configuration) #8 sheetmetal screws. Y B. Feed cord from blower through strain relief. Y C. Secure strain relief with screws. Y D. Attach strain relief to downdraft near junction box. Y E. Connect cord to downdraft at 6 pin connector. Y F. Connect blower to ductwork. Step 7: Mount Integral Blower or Outlet Duct Transition for Remote Blower Integral Blower VTN600CV2C (see Figures 10 and 12 for further detail): Y G. Place the cooktop in countertop opening with the rear edge of cooktop overlapping the front edge of the vent. Make sure rear edge of cooktop does not bind against front of snorkel. Follow the manufacturer's installation Instructions for installing gasket strips, protective heat tape (if required), securing the cooktop to the countertop and making the cooktop electrical and/or gas connections. Note: Check boxes as tasks are completed.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Step 7: Mount Integral Blower or
Outlet Duct Transition for Remote or
Inline Blower
Integral Blower
(see Figures 9 and 11 for
further detail):
Y
A. Attach blower in front of round
exhaust outlet with 4-6 (depending on
configuration) #8 sheetmetal screws.
Y
B. Feed cord
from blower
through strain
relief.
Y
C. Secure strain relief with screws.
Y
D. Attach strain relief to downdraft near
junction box.
Y
E. Connect cord to downdraft at 6 pin
connector.
Y
F. Connect blower to ductwork.
Fig. 9 – Internal Blower
13
Step 7: Mount Integral Blower or
Outlet Duct Transition for Remote
Blower
Integral Blower VTN600CV2C
(see Figures
10 and 12 for further detail):
Y
G. Place the cooktop in countertop ope-
ning with the rear edge of cooktop over-
lapping the front edge of the vent. Make
sure rear edge of cooktop does not bind
against front of snorkel. Follow the
manufacturer’s installation Instructions
for installing gasket strips, protective
heat tape (if required), securing the cook-
top to the countertop and making the
cooktop electrical and/or gas connec-
tions.
Note: Check boxes as tasks are completed.
Internal Blower
Strain Relief
6 Pin
Connector