Remote or Inline Blower (see Figures 10 and 11 for further detail): Y A. Remove junction box cover and connect conduit with 5 wires from remote blower. Hook up wires per Wiring.Fig. 10. Replace junction box cover. Y B. Attach Duct Transition Box at mounting holes with sheetmetal screws. Y C. Feed remote blower pigtail through strain relief. Y D. Attach strain relief to downdraft near junction box. Y E. Connect pigtail to downdraft at 6 pin connector. Y F. Run pigtail wires to junction box. Y G. Inside junction box, connect conduit with five wires from remote or inline blower. Use a conduit connector to secure. Integral Blower VTN600CV2C (see Figures 10 and 12 for further detail): Note: Blower and duct transition box may be installed with duct outlet left, down or right. Install blower or duct transition in such a way that access panels can be removed for service. Y H. Place the cooktop in countertop opening with the rear edge of cooktop overlapping the front edge of the vent. Make sure rear edge of cooktop does not bind against front of snorkel. Follow the manufacturer's installation Instructions for installing gasket strips, protective heat tape (if required), securing the cooktop to the countertop and making the cooktop electrical and/or gas connections. Note: Check boxes as tasks are completed. 6 Pin Connector Junction Box Duct Transition Box Strain Relief Remote Blower Pigtail Fig. 10 - Remote Blower 14 Conduit To Remote Blower

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Remote or Inline Blower
(see Figures 10
and 11 for further detail):
Y
A. Remove junction box cover and
connect conduit with 5 wires from remote
blower. Hook up wires per Wiring.Fig. 10.
Replace junction box cover.
Y
B. Attach Duct Transition Box at moun-
ting holes with sheetmetal screws.
Y
C. Feed remote blower pigtail through
strain relief.
Y
D. Attach strain relief to downdraft near
junction box.
Y
E. Connect pigtail to downdraft at 6 pin
connector.
Y
F. Run pigtail wires to junction box.
Y
G. Inside junction box, connect conduit
with five wires from remote or inline blo-
wer. Use a conduit connector to secure.
Fig. 10 – Remote Blower
14
Integral Blower VTN600CV2C
(see Figures
10 and 12 for further detail):
Note:
Blower and duct transition box may
be installed with duct outlet left, down or
right. Install blower or duct transition in
such a way that access panels can be
removed for service.
Y
H. Place the cooktop in countertop ope-
ning with the rear edge of cooktop over-
lapping the front edge of the vent. Make
sure rear edge of cooktop does not bind
against front of snorkel.
Follow the manufacturer’s installation
Instructions for installing gasket strips,
protective heat tape (if required), secu-
ring the cooktop to the countertop and
making the cooktop electrical and/or gas
connections.
Note: Check boxes as tasks are completed.
Strain Relief
Remote Blower
Pigtail
6 Pin Connector
Junction Box
Duct Transition Box
Conduit To
Remote Blower