Power Range 1000-3000 VA 230 V

Page 47 highlights

9.2 Power Range 1000-3000 VA (230 V) Tower Rackmount (2U) Input Output Battery Physical Environment Warranty International 230V Model International 230V Model Voltage (International) Voltage Range (International) Frequency Power Factor Topology Voltage (International) Capacity (VA) Capacity (W) Frequency Wave Form Load Power Factor Efficiency AC/DC/AC Rated Current (International) Overload Capacity Crest Factor DC Voltage (Tower & 2U) Backup Time (Tower & 2U) Interface Dimensions (Tower) Dimensions (2U) Weight (Tower/2U) Line Cord (International) Receptacles (Tower/2U) International Operating Temperature Altitude UT1E1E010C6 UT1E1E015C6 UT1E1E020C6 UT1E1E030C6 UT1E1E010C6R KB2 UT1E1E015C6R UT1E1E020C6R UT1E1E030C6R KB2 KB2 KB2 230 VAC (161 - 276 V) +20% to -30% 50 / 60 Hz auto sensing Greater than 0.97 True on-line, Double conversion Input PF correction 230 VAC 1000 VA 700 W 1500 VA 2000 VA 1050 W 1400 W 50 / 60 Hz auto sensing* Sine wave, zero transfer time 0.70 3000 VA 2100 W Greater than 86% Greater than 85% 4.3 A 6.5 A 8.7 A 13 A 125% for 1 min., 150% for 10 sec. 125% for 1 min., 130% for 10 sec. 3.0 at full load 2.5 at full load 36 V / 12 V 72V / 12 V 72V / 12 V 9 AH x 3 7.2 AH x 6 9 AH x 6 7 min 6 min 6 min 5 min (full load) (full load) (full load) (full load) RS-232 and USB standard RemotEye II® and EMD option 16.5"L x 6.0"W x 9.4"H 16.7" L x 8.9" W x 14.2" H 16.7"L x 16.9"W x 3.5"H "25.0""L x 16.9""W x 3.5""H" 35.6 lbs / 37.6 lbs 37.4 lbs / 68.4 lbs / 37.6 lbs 69.5 lbs IEC 320 72.6 lbs / 71.5 lbs IEC 320 (4 / 4) IEC 320 (8 / 8) 32 - 104°F (0 - 40°C) 11,500 ft (3500 m) above sea level Three years on electronics Two years full replacement on battery (See Toshiba warranty policy for full details.) * Output frequency can hard set at 50 or 60 Hz by installing an optional software upgrade. This upgrade enables the user to select a fixed output frequency and simultaneously disables the bypass mode. Standards - Safety: EN50091-1-1, Emissions: EN50091-2, Immunity: EN50091-2 B (1000-1500 VA) 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

25
9.2
Power Range 1000-3000 VA (230 V)
Tower
International
230V Model
UT1E1E010C6
UT1E1E015C6
UT1E1E020C6
UT1E1E030C6
Rack-
mount
(2U)
International
230V Model
UT1E1E010C6R
KB2
UT1E1E015C6R
KB2
UT1E1E020C6R
KB2
UT1E1E030C6R
KB2
Input
Voltage
(International)
230 VAC (161 – 276 V)
Voltage Range
(International)
+20% to -30%
Frequency
50 / 60 Hz auto sensing
Power Factor
Greater than 0.97
Topology
True on-line, Double conversion Input PF correction
Output
Voltage
(International)
230 VAC
Capacity (VA)
1000 VA
1500 VA
2000 VA
3000 VA
Capacity (W)
700 W
1050 W
1400 W
2100 W
Frequency
50 / 60 Hz auto sensing*
Wave Form
Sine wave, zero transfer time
Load Power
Factor
0.70
Efficiency
AC/DC/AC
Greater than 86%
Greater than 85%
Rated Current
(International)
4.3 A
6.5 A
8.7 A
13 A
Overload
Capacity
125% for 1 min., 150% for 10 sec.
125% for 1 min.,
130% for 10 sec.
Crest Factor
3.0 at full load
2.5 at full load
Battery
DC Voltage
(Tower & 2U)
36 V / 12 V
9 AH x 3
72V / 12 V
7.2 AH x 6
72V / 12 V
9 AH x 6
Backup Time
(Tower & 2U)
7 min
(full load)
6 min
(full load)
6 min
(full load)
5 min
(full load)
Interface
RS-232 and USB standard RemotEye II® and EMD option
Physical
Dimensions
(Tower)
16.5”L x 6.0”W x 9.4”H
16.7" L x 8.9" W x 14.2" H
Dimensions
(2U)
16.7”L x 16.9”W x 3.5”H
"25.0""L x 16.9""W x 3.5""H"
Weight
(Tower/2U)
35.6 lbs /
37.6 lbs
37.4 lbs /
37.6 lbs
68.4 lbs /
69.5 lbs
72.6 lbs / 71.5 lbs
Line Cord
(International)
IEC 320
Receptacles
(Tower/2U)
International
IEC 320 (4 / 4)
IEC 320 (8 / 8)
Environ-
ment
Operating
Temperature
32 – 104
°
F (0 – 40
°
C)
Altitude
11,500 ft (3500 m) above sea level
Warranty
Three years on electronics
Two years full replacement on battery (See Toshiba warranty policy for full details.)
*
Output frequency can hard set at 50 or 60 Hz by installing an optional software upgrade.
This upgrade enables the user to
select a fixed output frequency and simultaneously disables the bypass mode.
Standards - Safety: EN50091-1-1, Emissions: EN50091-2, Immunity: EN50091-2 B (1000-1500 VA)