Toshiba UT1A1A010C6 User Guide - Page 49

Limitations And Exclusions - price

Page 49 highlights

LIMITATIONS AND EXCLUSIONS 1. This limited warranty shall not cover the UPS, UPS parts, or BATTERY during their respective warranty periods, if the following storage, maintenance, installation, operating conditions are not met throughout the warranty periods (5 conditions below): Valve Regulated Lead Acid (VRLA) Batteries for Toshiba UPS Required Operating, Installation, and Maintenance Conditions 1. Temperature Annual Average Temperature is to be 77°F (25 °C) with no greater temperature of 89 °F (32 °C) for more than 30 days Maximum Number of Cycles (24 Months)*** Discharge Time Battery > 9 AHr Battery < 9 AHr 2. Maximum # of Full Charge/Discharge Cycles 30 min 15 min 10 min 20 25 32 69 86 110 5 min 38 130 *** > 9AHr Typically extended runtimes < 9AHr Typically Single Phase Systems. 3. Storage While UPS is in Transit or in storage, it must always be in a suitable temperature (as stated above) 4. External Battery Parallel battery string applications must be approved by TIC in writing 5. Idle Batteries User must recharge the batteries if not in use (charged) for more than 6 months Credit for Replacement Battery When Approved Warranty Time from Shipments UPS Batteries Cost to Customer Months % Credit % List Price 0-24 100 0 25-30 55 45 31-36 45 55 37-42 35 65 43-48 25 75 49-54 15 85 55-60 5 95 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

LIMITATIONS AND EXCLUSIONS
1.
This limited warranty shall not cover the UPS, UPS parts, or BATTERY during their
respective warranty periods, if the following storage, maintenance, installation, operating
conditions are not met throughout the warranty periods (5 conditions below):
Valve Regulated Lead Acid (VRLA) Batteries for Toshiba UPS Required Operating, Installation, and
Maintenance Conditions
1. Temperature
Annual Average Temperature is to be 77
°
F (25
°
C) with no greater
temperature of 89
°
F (32
°
C) for more than 30 days
Maximum Number of Cycles (24 Months)***
Discharge Time
Battery > 9 AHr
Battery < 9 AHr
30 min
20
69
15 min
25
86
10 min
32
110
5 min
38
130
2. Maximum # of Full
Charge/Discharge
Cycles
*** > 9AHr Typically extended runtimes < 9AHr Typically Single Phase
Systems.
3. Storage
While UPS is in Transit or in storage, it must always be in a suitable
temperature (as stated above)
4. External Battery
Parallel battery string applications must be approved by TIC in writing
5. Idle Batteries
User must recharge the batteries if not in use (charged) for more than 6
months
Credit for Replacement Battery When Approved Warranty
Time from Shipments
UPS Batteries
Cost to Customer
Months
% Credit
% List Price
0-24
100
0
25-30
55
45
31-36
45
55
37-42
35
65
43-48
25
75
49-54
15
85
55-60
5
95
27