Tripp Lite BP48V Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G
Tripp Lite BP48V Manual
View all Tripp Lite BP48V manuals
Add to My Manuals
Save this manual to your list of manuals |
Tripp Lite BP48V manual content summary:
- Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 1
Eaton Tripp Lite SmartOnline Series Tower Advanced Users Guide SU700XLCD SU1000XLCD SU1500XLCD SU2200XLCD SU3000XLCD BP36V BP48V BP96V p/n: 614-21326 Revision 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 2
. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 3
.ERATOR'S MANUAL - Refer to your operator's manual for additional information, such as important operating and maintenance instructions. This levels are resent within the system. It should be opened exclusively by qualified service personnel. • The system must be properly grounded at all times. • - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 4
Product Safety • To connect the UPS, instructions and operation described in the manual must be followed in the indicated order. • local Eaton representative. • All repairs and service should be performed by AUTHORIZED SERVICE PERSONNEL ONLY. There are NO USER SERVICEABLE PARTS inside the UPS. • For - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 5
Event Log ...27 6 Maintenance...29 6.1 Equipment care...29 6.2 Storing the equipment ...29 6.3 When to replace batteries ...29 6.4 Replacing batteries ...30 6.5 Recycling the used equipment ...33 7 Troubleshooting ...35 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 v - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 6
Table of Contents 7.1 Typical Alarms and Faults ...35 7.2 Silencing the Alarm ...39 7.3 Service and Support ...39 8 Specifications ...41 8.1 Model Specifications ...41 vi Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 7
recommend that you take the time to read this manual to take full advantage of the many features of presenting the safety instructions. Then follow the indications in this manual. To discover Eaton will process products at the end of their service life in compliance with local regulations. Tripp Lite - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 8
all local regulations concerning waste. At the end of its service life, the product must be transported to a processing center it and power quality can be erratic. These power problems have the potential to corrupt critical data, destroy unsaved Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 9
Module Network Card 2m cable 36V EBM Tower 2m cable 48V EBM Tower 2m cable 96V EBM Tower Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 3 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 10
USB communication port 11 RPO port (Remote Power Off) 12 Output AC SU1500XLCD 4 2 3 11 8 9 10 5 1 6 7 SU3000XLCD 10 2 9 3 11 8 4 5 6 7 1 4 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 11
to the other battery modules) 14 Connectors for automatic recognition of battery modules BP96V 13 14 14 13 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 5 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 12
Rear Panels 6 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 13
damage claim within 15 days to your service representative. NOTE Check the battery recharge the UPS. Contact your service representative. 3.2 Checking the communication cable 4 Safety instructions 5 Quick start 6 UPS accessories, refer to specific user manuals to check the tower installation with - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 14
on the cable or disconnect it. 4. Connect the internal battery connector. 5. Reassemble in the reverse order. See Figure 5 . 8 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 15
EBM Accessory Kit 1 SmartOnline EBM 2 Battery power cable, attached with battery detection cable 3 Quick start 4 Safety instructions 1 4 3 2 1. Plug the EBM power cable(s) into the battery connector(s). Up to 4 EBMs may cable. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 9 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 16
SmartOnline EBM Installation 3. Connect the battery detection cable(s) to the connector of the UPS and of the EBM(s). Figure 7. Connecting the SmartOnline EBMs 10 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 17
Battery mode. On The UPS is on Bypass mode. On The UPS has an active alarm or fault. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 11 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 18
, the first line of LCD will cycle between fault/alarm message and UPS mode, see troubleshooting page for additional information. Figure 9. LCD Description LCD mode description Load/equipment status ONLINE MODE for shutdown. 12 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 19
voltage screen tracks the charge level of your connected battery bank in terms of voltage and charge percentage. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 13 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 20
USED is used to reset the power used. FACTORY SETT command is used to restore factory settings. 14 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 21
function for OUTPUT RELAY. Select output signal function for OUTPUT DB9-1. Select output signal function for OUTPUT DB9-8. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 15 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 22
is used to restore factory settings. Sets displayed language for Menus, status and alarms. UPS fault, Event log data and settings are in all supported languages. Enables or disables the audible alarm. Sets the UPS output voltage, UPS must be in standby to choose output voltage setting. 16 Tripp - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 23
set percentage of battery charge is reached. The alarm triggers when the set battery time remaining is reached. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 17 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 24
RS232. Sets events or fault that will actuate Output signal parameters through external contact connector or RS232. 18 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 25
Play 7 UPS ON Output UPS ON 8 BAT Mode Output - 9 +5V Output Power supply for external signals or options Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 19 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 26
, the input power must be disconnected from the UPS when the Remote Power Off function is activated. 20 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 27
is nearly empty Battery fault UPS is operating in Bypass mode Load is powered (from inverter or bypass) Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 21 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 28
's ethernet port and a network jack It is not necessary to shutdown the UPS before installing a communication card. 22 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 29
Lite by Eaton also offers Cybersecurity Best Practices whitepapers to its customers, referenced at www.Eaton.com/cybersecurity. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 23 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 30
Cybersecurity 24 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 31
. Optional High Efficiency and Energy Saving settings minimize heat contribution to the rack environment. See section 4.5 User Settings. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 25 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 32
recommends to use the HE mode only to protect IT equipment. To set the High Efficiency mode: 26 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 33
as the first event. Press the ESC button twice to exit back to the "4.3 UPS Home Menu" menu . Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 27 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 34
Retrieving the Event Log 28 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 35
rated for a 3-5 year service life. The length of service life varies, depending on the 25 °C). Batteries used beyond expected service life will often have severely do not use them. Contact your service representative. 6.3 When to replace batteries service representative to order new batteries. Tripp - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 36
replacing batteries, replace with the same type and number of batteries or battery packs. Contact your service representative to order new batteries. • Proper disposal of batteries is required. Refer to your heavy batteries. 30 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 37
Figure 11. Battery Replacement 1 2 Replacing batteries 4 3 6 7 5 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 31 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 38
pack, and slide the pack out slowly on to a flat and stable surface. Use two hands to support the battery pack. See 6.5 Recycling the used equipment for proper disposal. 5. Verify that the replacement batteries a battery test. 32 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 39
of electric CAUTION: REFsEhRocTkOsOymPEbRoAl.TOR'S MANUAL - Refer to your operator's manual for additional information, such as important operating and maintenance instructions. This symbol indicates that you should Corporation. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 33 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 40
Recycling the used equipment 34 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 41
Chapter 7 Troubleshooting 7.1 Typical Alarms and Faults The SmartOnline series UPS units are designed for durable, automatic operation and also alert you whenever potential operating problems may occur. Usually the alarms shown by the control panel do not mean that the output power is affected. - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 42
the UPS is not restricted. Restart the UPS. If the condition continues to persist, contact your service representative. The UPS does not start The input source is not connected correctly. Check the input connections damaged 36 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 43
AC mains Please check ambient temperature and if the ventilation is blocked Check AC Freq Check AC Volt Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 37 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 44
pre-alarm setting and load Output power overload, Max (P,S) > L2 (L2 = 102%) Please check the load capacity 38 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 45
alarm silencing. 7.3 Service and Support If you have any questions or problems with the UPS, call the Eaton technical support helpdesk at 800-356- 5737 or your local service representative and ask for for all warrantied units. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 39 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 46
Service and Support 40 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 47
6.3 x 9.9 x 17.0 / 160 x 252 x 434 8.4 x 13.6 x 16.2 / 214 x 346 x 412 8.4 x 13.6 x 16.2 / 214 x 346 x 412 6.3 x 9.9 x 15.2 / 160 x 252 x 387 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 41 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 48
: ±0.5% of auto-selected nominal frequency) Battery Mode ±3% 79.5% 82% 82% 84% 84% ±0.5% of auto-selected nominal frequency 42 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 49
L5-20R Group 1 (2) NEMA 5-20R Group2 NA SU3000XLCD (1) NEMA L5-30R Primary (2) NEMA 5-20R Group1 (2) NEMA 5-20R Group2 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 43 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 50
: 36Vdc- 2 x 3 x 12V. 9Ah BP48V: 48Vdc- 2 x 4 x 12V. 9Ah BP96V: 96Vdc- 2 x 8 x 12V. 9Ah Sealed, maintenance-free, valve-regulated, lead-acid, with minimum 3-year float service life at 25 °C (77 °F). Lifetime is reduced above 25°C (77°F) 400 mm / 15.75 in 44 Tripp Lite by Eaton SmartOnline Series - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 51
Model Specifications Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 45 - Tripp Lite BP48V | Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 52
614-2132601 614-21326 01
p/n:614-21326
Revision01
SU700XLCD
SU1000XLCD
SU2200XLCD
SU3000XLCD
BP36V
BP48V
BP96V
SU1500XLCD
TowerAdvancedUsersGuide
Eaton Tripp Lite SmartOnline Series