Tripp Lite BP48V Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 23
Table 7. User Settings Continued, Main Menu Screen, Submenu, Menu Function
View all Tripp Lite BP48V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
User Settings Table 7. User Settings (Continued) Main Menu Screen Submenu OUTPUT FREQUENCY HIGH EFFIC. MODE OVERLOAD PREALARM COLD START AUTO RESTART ON / OFF SETTINGS AUTO START START ON BYPASS SLEEP MODE SITE WIRING FLT BATTERY SETTINGS AUTO BAT TEST RESTART LEVEL BATT LOW LEVEL BATT LOW TIME Submenu AUTOSENSING* (Default) [AUTO SENSING] [FREQ CONV. 50HZ] [FREQ CONV. 60HZ] DISABLED* (Default) [ENABLED] [DISABLED] 102%* (Default) [50%] [55%]....[100%][102%] ENABLED* (Default) [ENABLED] [DISABLED] ENABLED* (Default) [ENABLED] [DISABLED] ENABLED* (Default) [ENABLED] [DISABLED] ENABLED* (Default) [ENABLED] [DISABLED] ENABLED* (Default) [ENABLED] [DISABLED] ENABLED* (Default) [ENABLED] [DISABLED] MONTHLY*(Default) [NO TEST] [DAILY] [WEEKLY] [MONTHLY] 0%* (Default) [0%]....[100%] 0%* (Default) [0%]....[100%] 3 MIN* (Default) [0MIN] [3MIN] .. [60MIN] Menu Function Sets the output frequency, output frequency follows the input frequency, Power the output from bypass for high efficiency Load % when overload alarm occurs Allows the SmartOnline UPS to start on battery power. Allows the SmartOnline UPS to restart automatically when mains recovers after a complete battery discharge. The SmartOnline UPS starts up as soon as mains power is available. Allows the SmartOnline UPS to start in bypass mode. If Disabled, LCD and communication will turn off immediately afterSmartOnline UPS is OFF. If Enabled, LCD and communication stays ON 1h30 min after the SmartOnline UPS is OFF. Prevents the SmartOnline UPS from starting in case of phase to neutral wire swapping or improper grounding, Allows the SmartOnline UPS to perform an automatic battery test. Allows the SmartOnline UPS to restart when the set percentage battery charge is reached. The alarm triggers when the set percentage of battery charge is reached. The alarm triggers when the set battery time remaining is reached. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 17