Tripp Lite BP48V Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 22

UserSettings

Page 22 highlights

User Settings Table 6. Display Functions (Continued) Main Menu Submenu EVENT LOG IDENTIFICATION Display Information or Menu function Event log has 50 items to show what happened. This menu shows IDENTIFICATION information. 4.5 User Settings The following table displays the options that can be changed by the user. From the UPS Home Menu press the button. This will open the Main Menu Screen . To select a menu option use the or buttons. Press the button to validate the selected item. Pressing the ESC button will exit to the previous menu level / screen. Table 7. User Settings Main Menu Screen CONTROL LOCAL SETTINGS IN / OUT SETTINGS Submenu GO TO BYPASS / GO BACK NORMAL BATTERY TEST RESET FAULT ST CLEAR EVENT LOG RESET KWH USED FACTORY SETT LANGUAGE AUDIBLE ALARM OUTPUT VOLTAGE Submenu GO TO BYPASS / GO BACK NORMAL? BATTERY TEST? RESET FAULT ST? CLEAR EVENT LOG? RESET KWH USED? FACTORY SETT? ENGLISH* (Default) [FRANCAIS] [ESPANOL] ENABLED* (Default) [ENABLED] [DISABLED ON BAT] [ALWAYS DISABLED] 120V* (LV Default) [100V] [110V] [120V] [125V] 208V* (HV Default) [200V] [208V] [220V] [230V] [240V] Menu Function GO TO BYPASS command is used to force ups to bypass mode from ONLINE MODE. GO BACK NORMAL command is used to comeback to line mode from BYPASS MODE. BATTERY TEST command is used to start battery test. RESET FAULT ST command is used to reset all faults. But some faults may not be cleared. CLEAR EVENT LOG command is used to clear all the event log. RESET KWH USED is used to reset the power used. FACTORY SETT command is used to restore factory settings. Sets displayed language for Menus, status and alarms. UPS fault, Event log data and settings are in all supported languages. Enables or disables the audible alarm. Sets the UPS output voltage, UPS must be in standby to choose output voltage setting. 16 Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

16
Tripp Lite by Eaton SmartOnline Series User Guide 614-21326—Rev 01
Table 6. Display Functions (Continued)
Main Menu
Submenu
Display Information or Menu function
EVENTLOG
Eventloghas50itemstoshowwhat
happened.
IDENTIFICATION
ThismenushowsIDENTIFICATION
information.
4.5 UserSettings
The following table displays the options that can be changed by the user. From the
UPS Home Menu
press the
button. This will open the
Main Menu Screen
. To select a menu option use the
or
buttons. Press the
button to validate the selected item. Pressing the ESC button will exit to the previous menu level / screen.
Table 7. User Settings
Main Menu Screen
Submenu
Submenu
Menu Function
CONTROL
GOTOBYPASS/GOBACK
NORMAL
GOTOBYPASS/GOBACK
NORMAL?
GOTOBYPASScommandis
usedtoforceupstobypass
modefromONLINEMODE.
GOBACKNORMALcommand
isusedtocomebacktoline
modefromBYPASSMODE.
BATTERYTEST
BATTERYTEST?
BATTERYTESTcommandis
usedtostartbatterytest.
RESETFAULTST
RESETFAULTST?
RESETFAULTSTcommandis
usedtoresetallfaults.But
somefaultsmaynotbe
cleared.
CLEAREVENTLOG
CLEAREVENTLOG?
CLEAREVENTLOGcommand
isusedtoclearalltheevent
log.
RESETKWHUSED
RESETKWHUSED?
RESETKWHUSEDisusedto
resetthepowerused.
FACTORYSETT
FACTORYSETT?
FACTORYSETTcommandis
usedtorestorefactory
settings.
LOCALSETTINGS
LANGUAGE
ENGLISH*(Default)
[FRANCAIS][ESPANOL]
Setsdisplayedlanguagefor
Menus,statusandalarms.
UPSfault,Eventlogdataand
settingsareinallsupported
languages.
AUDIBLEALARM
ENABLED*(Default)
[ENABLED][DISABLEDON
BAT][ALWAYSDISABLED]
Enablesordisablesthe
audiblealarm.
IN/OUTSETTINGS
OUTPUTVOLTAGE
120V*(LVDefault)[100V]
[110V][120V][125V]
208V*(HVDefault)[200V]
[208V][220V][230V][240V]
SetstheUPSoutputvoltage,
UPSmustbeinstandbyto
chooseoutputvoltagesetting.
UserSettings