Tripp Lite BP48V Eaton Tripp Lite SmartOnline Series Tower UPS Advanced User G - Page 31
Operation
View all Tripp Lite BP48V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Chapter 5 Operation 5.1 Start-up and Normal operation To start the UPS: 1. Verify that the internal batteries are connected. See 3.3 SmartOnline UPS Installation. 2. If optional EBMs are installed, verify that the EBM are connected to the UPS. See section 3.3 SmartOnline UPS Installation. 3. Verify that the UPS power cord is plugged in. 4. The UPS front panel display illuminates and displays the UPS Home Menu see 4.3 UPS Home Menu. 5. Press the button on the UPS front panel for at least 2 seconds. The UPS display will read "UPS Starting" . 6. Check the UPS front panel display for active alarms or notices. If the indicator is on, do not proceed until all alarms are cleared. Check the UPS status from the front panel to view the active alarms. Correct the alarms and restart if necessary. See 7.1 Typical Alarms and Faults . 7. Verify that the indicator illuminates solid, indicating that the UPS is operating normally and any loads are powered and protected. The UPS should be in normal mode. 5.2 Starting the UPS on Battery NOTE By default the "Cold Start or battery start setting is enabled from the factory. To start the UPS on battery: 1. Press the button on the UPS front panel until the UPS front panel display illuminates and shows a status of "UPS Starting...". The UPS transfers from Standby mode to Battery mode. The illuminates solid. The UPS supplies power to your equipment. indicator 2. Check the UPS front panel display for active alarms . Resolve any active alarms before continuing. See the "7.1 Typical Alarms and Faults " section . 5.3 UPS Shutdown To shut down the UPS: 1. Press the button on the front panel for three seconds. The UPS then transfers to Standby mode and the indicator turns off. If utility power is removed from the input of the UPS while in the "Standby Mode" the system will then begin to shut down after 10 seconds. 5.4 Operating modes The Tripp Lite by Eaton SmartOnline UPS front panel indicates the status through the front panel indicators, See section 4.1 Control Panel. Online Mode During Online mode, the indicator illuminates solid and the UPS is powered from the utility. The UPS monitors and charges the batteries as needed and provides filtered power protection to your equipment. Optional High Efficiency and Energy Saving settings minimize heat contribution to the rack environment. See section 4.5 User Settings. Tripp Lite by Eaton SmartOnline Series User Guide 614-21326-Rev 01 25