Yes/E, Set Delay Time, Set Modulation, Set Attenuator

Page 36 highlights

Auto 5 KHz 6.25 KHz 7.5 KHz 8.33 KHz 10 KHz 12.5 KHz 15 KHz 20 KHz 25 KHz 50 KHz 100 KHz 2. Scroll to the step you want to set. Press Yes/E or push the scroll control knob when you have finished editing to save the entry, exit, and display the previous menu. Set Delay Time For: 0, 1, 2, 5, 10, 30 seconds: Sets the time to stay on that frequency after the transmission ends. NOTE: You can wait for a delayed reply to that transmission. If set to 0, the search starts as soon as transmission ends; if there is a reply after 1 second, you may miss it. Increasing this time will slow down the overall search but allow time for a reply to be heard. For: -2. -5, -10, -30 seconds: If negative values are set for a frequency, the scanner stays on that frequency for the set amount of time after receiving a signal. For example, if you set this value to -2 seconds, you will only hear the first 2 seconds of a 10-second transmission. Scroll to the desired delay time and press Yes/E to save and exit. Set Modulation When you select AUTO, the radio uses the default mode for that frequency. If you want to specifically change the mode and bandwidth, you can change it manually. Modulation options are: • Auto • AM • NFM • FM • WFM • FMB NOTE: Press FUNC + 9(mod) in Search mode to override modulation. Set Attenuator Press FUNC + 7/att to add an attenuator per frequency for an individual search bank. If a strong signal source exists near the desired frequency or at the image frequency, it may interfere with the desired frequency's reception. Turning on ATT weakens the received signal but may improve communication clarity. Normally, use it with OFF. 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

36
Auto
5 KHz
6.25 KHz
7.5 KHz
8.33 KHz
10 KHz
12.5 KHz
15 KHz
20 KHz
25 KHz
50 KHz
100 KHz
2.
Scroll to the step you want to set. Press
Yes/E
or push the scroll control knob
when you have
nished editing to save the entry, exit, and display the previous
menu.
Set Delay Time
For: 0, 1, 2, 5, 10, 30 seconds:
Sets the time to stay on that frequency after the transmission ends.
NOTE: You can wait for a delayed reply to that transmission. If set to 0, the search
starts as soon as transmission ends; if there is a reply after 1 second, you may miss
it. Increasing this time will slow down the overall search but allow time for a reply to
be heard.
For: -2. -5, -10, -30 seconds:
If negative values are set for a frequency, the scanner stays on that frequency for the
set amount of time after receiving a signal. For example, if you set this value to -2
seconds, you will only hear the
rst 2 seconds of a 10-second transmission.
Scroll to the desired delay time and press
Yes/E
to save and exit.
Set Modulation
When you select
AUTO
, the radio uses the default mode for that frequency. If you
want to speci
cally change the mode and bandwidth, you can change it manually.
Modulation options are:
Auto
AM
NFM
FM
WFM
FMB
NOTE: Press
FUNC
+
9(mod)
in Search mode to override modulation.
Set Attenuator
Press
FUNC
+
7/att
to add an attenuator per frequency for an individual search
bank.
If a strong signal source exists near the desired frequency or at the image frequency,
it may interfere with the desired frequency’s reception. Turning on ATT weakens the
received signal but may improve communication clarity. Normally, use it with OFF.