or 1200 CFM Exterior or In-Line Ventilator Installation

Page 12 highlights

Interior Ventilator Dimensions (DTWS Slim Traditional Wall Hoods) 30"W. 36"W. 42"W. A 15-3/4" (40.0 cm) 18-3/4" (47.6 cm) 21-3/4" (55.2 cm) Top view A 1-1/8" (2.9 cm) 5-9/16" (14.3 cm) 120 V power supply 5-1/8" (13.0 cm) 7" (17.8 cm) 11" dia. duct (27.9 cm) location 300 or 600 CFM Interior Ventilator Installation for 30"30,03o6r "44,0&CF4M2*"* models Interior Ventilator Installation 30", 36", & 42" models Top view 23-15/16" (60.1 cm) 7-7/8" (20.0 cm) 1-1/8" (2.9 cm) 6" (15.2 cm) 19" (48.3 cm) 120 V 10" (25.4 cm) dia. duct location 1200 CFM Interior Ventilator Installation for 4888"0 mCFoMdels Interior Ventilator Installation 48" models 22 Exterior Ventilator Dimensions (DTWS Slim Traditional Wall Hoods) 30"W. 36"W. 42"W. A 15-3/4" (40.0 cm) 18-3/4" (47.6 cm) 21-3/4" (55.2 cm) Top view A 1-1/8" (2.9 cm) 5-9/16" (14.3 cm) 120 V power supply 5-1/8" (13.0 cm) 11" (27.9 cm) 8" (20.3 cm)* dia. duct location * 8" to 10" transition to be acquired locally. 900 or 1200 CFM Exterior or In-Line Ventilator Installation for 30",93006o"r 1&20402C"FMmodels Exterior Ventilator Installation 30", 36" & 42" models Top view 23-15/16" (60.1 cm) 7-7/8" (20.0 cm) 1-1/8" (2.9 cm) 6" (15.2 cm) 120 V 19" (48.3 cm) 10" (25.4 cm) dia. duct location 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation fo1r20408o"r 1m50o0dCeFMls Exterior Ventilator Installation 48" models 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

23
22
120 V
power supply
5-9/16”
(14.3 cm)
A
5-1/8”
(13.0 cm)
11”
(27.9 cm)
8” (20.3 cm)*
dia. duct
location
1-1/8”
(2.9 cm)
A
30”W.
15-3/4” (40.0 cm)
36”W.
18-3/4” (47.6 cm)
42”W.
21-3/4” (55.2 cm)
120 V
7-7/8” (20.0 cm)
1-1/8” (2.9 cm)
6” (15.2 cm)
19”
(48.3 cm)
23-15/16”
(60.1 cm)
10” (25.4 cm)
dia. duct
location
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for 30”, 36” & 42” models
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for 48” models
120 V
power supply
5-9/16”
(14.3 cm)
A
5-1/8”
(13.0 cm)
11”
(27.9 cm)
7” (17.8 cm)
dia. duct
location
1-1/8”
(2.9 cm)
A
30”W.
15-3/4” (40.0 cm)
36”W.
18-3/4” (47.6 cm)
42”W.
21-3/4” (55.2 cm)
300 or 600 CFM Interior Ventilator Installation
for 30”, 36”, & 42” models
(DTWS Slim Traditional Wall Hoods)
(DTWS Slim Traditional Wall Hoods)
Exterior Ventilator Dimensions
Interior Ventilator Dimensions
10” (25.4 cm)
dia. duct
location
120 V
7-7/8” (20.0 cm)
1-1/8” (2.9 cm)
6” (15.2 cm)
19”
(48.3 cm)
23-15/16”
(60.1 cm)
Top view
Top view
Top view
Top view
1200 CFM Interior Ventilator Installation
for 48” models
* 8” to 10”
transition to be
acquired locally.