Viking DTWN3648SS Installation Instructions - Page 19

Built-In Island Custom Ventilator, System Dimensions

Page 19 highlights

Built-In Island Custom Ventilator System Dimensions (36"W./42"W. DICV Models) 11" (27.9 cm) 8" (20.3 cm) 1" (2.5 cm) 11" (27.9 cm) 7" (17.8 cm) 1" (2.5 cm) 5" (12.7cm) 11-3/4" (29.8 cm) 900, 1200 or 1500 CFM External** or In-Line Ventilator Installation A B C 16" (40.6 cm) 6" (15.2 cm) 2" (5.1 cm) 5" (12.7cm) 11-3/4" (29.8 cm) 300 or 600 CFM** Internal Ventilator Installation A B C 16" (40.6 cm) 6" (15.2 cm) 2" (5.1 cm) 11-1/8" (28.3 cm) 22-1/4" (56.5 cm) 21" (53.3 cm) 3/4" (1.9 cm) 120V 8" (20.3 cm) Round for Ventilation Duct* 11-1/8" (28.3 cm) 22-1/4" (56.5 cm) 21" (53.3 cm) 3/4" (1.9 cm) 120V 7" (17.8 cm) Round for Ventilation Duct* 900, 1200 or 1500 CFM External** or In-Line Ventilator Installation (10" diameter duct required) *Must purchase 8" diameter to 10" diameter transition locally. Transition should be installed past the duct cover. 300*** or 600 CFM** Internal Ventilator Installation (7" diameter duct required) 36" W. 42" W. A 35-5/8" (90.5 cm) 41-5/8" (105.7 cm) 36" W. 42" W. B 34-5/8" (87.9 cm) 40-5/8" (103.2 cm) 36" W. 42" W. C 17-13/16" (45.2 cm) 20-13/16" (52.9 cm) **1500 CFM external ventilator kit for installation with 42" W. island hood only. ***300 CFM ventilator kit for installation with 30" W. and 36" W. hoods only. 36 Built-In Island Custom Ventilator System Dimensions (54"W. DICV Models) 11" (27.9 cm) 10" (25.4 cm) 1" (2.5 cm) 5" (12.7cm) 11-3/4" (29.8 cm) 1200 CFM Internal and 900, 1200 or 1500 CFM External or In-Line Ventilator Installation 53-5/8" (136.2 cm) 52-5/8" (133.7 cm) 26-13/16" (68.1 cm) 24" (61.0 cm) 10" (25.4 cm) 2" (5.1 cm) 22-1/4" (56.5 cm) 11-1/8" (28.3 cm) 21" (53.3 cm) 3/4" (1.9 cm) 120V 10" (25.4 cm) Round for Ventilation Duct 1200 CFM Internal and 900, 1200 or 1500 CFM External or In-Line Ventilator Installation (10" diameter duct required) 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

37
36
Built-In Island Custom Ventilator
System Dimensions
(36”W./42”W. DICV Models
)
900, 1200 or 1500 CFM External**
or In-Line Ventilator Installation
300 or 600 CFM** Internal
Ventilator Installation
11”
(27.9 cm)
8”
(20.3 cm)
5”
(12.7cm)
11-3/4”
(29.8 cm)
1” (2.5 cm)
11”
(27.9 cm)
7”
(17.8 cm)
5”
(12.7cm)
11-3/4”
(29.8 cm)
1” (2.5 cm)
900, 1200 or 1500 CFM External**
or In-Line Ventilator Installation
(10” diameter duct required)
300*** or 600 CFM** Internal
Ventilator Installation
(7” diameter duct required)
120V
7” (17.8 cm) Round
for Ventilation Duct*
3/4”
(1.9 cm)
B
C
A
16”
(40.6 cm)
6”
(15.2 cm)
2”
(5.1 cm)
11-1/8”
(28.3 cm)
21”
(53.3 cm)
22-1/4”
(56.5 cm)
3/4”
(1.9 cm)
120V
8” (20.3 cm) Round for
Ventilation Duct*
11-1/8”
(28.3 cm)
21”
(53.3 cm)
22-1/4”
(56.5 cm)
B
C
A
6”
(15.2 cm)
2”
(5.1 cm)
16”
(40.6 cm)
*Must purchase 8” diameter to 10” diameter transition
locally. Transition should be installed past the duct cover.
A
36” W.
35-5/8” (90.5 cm)
42” W.
41-5/8” (105.7 cm)
***300 CFM ventilator kit for installation with 30” W. and 36” W. hoods only.
**1500 CFM external ventilator kit for installation with 42” W. island hood only.
B
36” W.
34-5/8” (87.9 cm)
42” W.
40-5/8” (103.2 cm)
C
36” W.
17-13/16” (45.2 cm)
42” W.
20-13/16” (52.9 cm)
Built-In Island Custom Ventilator
System Dimensions
(54”W. DICV Models
)
1200 CFM Internal and 900, 1200 or 1500
CFM External or In-Line Ventilator Installation
11”
(27.9 cm)
10”
(25.4 cm)
5”
(12.7cm)
11-3/4”
(29.8 cm)
1” (2.5 cm)
1200 CFM Internal and 900, 1200 or 1500
CFM External or In-Line Ventilator Installation
(10” diameter duct required)
10” (25.4 cm) Round for
Ventilation Duct
120V
3/4”
(1.9 cm)
11-1/8”
(28.3 cm)
21”
(53.3 cm)
22-1/4”
(56.5 cm)
10”
(25.4 cm)
24”
(61.0 cm)
26-13/16”
(68.1 cm)
52-5/8” (133.7 cm)
53-5/8” (136.2 cm)
2”
(5.1 cm)