Viking DTWN3648SS Installation Instructions - Page 16

Built-In Wall Custom Ventilator, System Dimensions

Page 16 highlights

Clearance Dimensions (DBCV Wall Custom Ventilator System) (913.46"cm) ((7611268672""t..mmo69 accinmmx..)) (Custom Hood) 33((796061""..t24mmoccaimmnx.)). NOTE: For best performance, it is recommended that the bottom of the hood be 30" (76.2 cm) to 36" (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood. 30 Built-In Wall Custom Ventilator System Dimensions (30"W./36"W./42"W. DBCV Models) 11" (27.9 cm) 8" (20.3 cm) 1" (2.5 cm) 11" (27.9 cm) 7" (17.8 cm) 1" (2.5 cm) 5" (12.7 cm) 11-3/4" (29.8 cm) 900 or 1200 CFM External or In-Line Ventilator Installation 5" (12.7 cm) 11-3/4" (29.8 cm) 300 or 600 CFM** Internal Ventilator Installation 6-1/8" (15.6 cm) 17-1/4" (43.8 cm) A C B 16" (40.6 cm) 6" (15.2 cm) 2" (5.1 cm) 120V 8" (20.3 cm) Round for External Ventilation Duct* 3/4" (1.9 cm) 6-1/8" (15.6 cm) 16" (40.6 cm) A C B 16" (40.6 cm) 6" (15.2 cm) 2" (5.1 cm) 120V 7" (17.8 cm) Round for External Ventilation Duct* 900 or 1200 CFM External or In-Line Ventilator Installation (10" diameter duct required) *Must purchase 8" diameter to 10" diameter transition locally. Transition should be installed past the duct cover. 300 or 600 CFM** Internal Ventilator Installation (7" diameter duct required) 3/4" (1.9 cm) 30" W. 36" W. 42" W. A 29-5/8" (75.2 cm) 35-5/8" (90.5 cm) 41-5/8" (105.7 cm) 30" W. 36" W. 42" W. B 28-3/8" (72.1 cm) 34-3/8" (87.3 cm) 40-3/8" (102.6 cm) 30" W. 36" W. 42" W. C 14-13/16" (37.6 cm) 17-13/16" (45.2 cm) 20-13/16" (52.9 cm) **300 CFM ventilator kit for installation with 30" W. and 36" W. hoods only. 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

31
30
Built-In Wall Custom Ventilator
System Dimensions
(30”W./36”W./42”W. DBCV Models
)
900 or 1200 CFM External or In-Line
Ventilator Installation
300 or 600 CFM** Internal
Ventilator Installation
A
30” W.
29-5/8” (75.2 cm)
36” W.
35-5/8” (90.5 cm)
42” W.
41-5/8” (105.7 cm)
11-3/4”
(29.8 cm)
1”
(2.5 cm)
11”
(27.9 cm)
8”
(20.3 cm)
5”
(12.7 cm)
11-3/4”
(29.8 cm)
1” (2.5 cm)
11”
(27.9 cm)
7”
(17.8 cm)
5”
(12.7 cm)
900 or 1200 CFM External or In-Line
Ventilator Installation
(10” diameter duct required)
300 or 600 CFM** Internal
Ventilator Installation
(7” diameter duct required)
B
C
A
16”
(40.6 cm)
6-1/8”
(15.6 cm)
16”
(40.6 cm)
6”
(15.2 cm)
2”
(5.1 cm)
120V
3/4”
(1.9 cm)
7” (17.8 cm) Round for
External Ventilation Duct*
B
C
A
17-1/4”
(43.8 cm)
6-1/8”
(15.6 cm)
16”
(40.6 cm)
6”
(15.2 cm)
2”
(5.1 cm)
120V
3/4”
(1.9 cm)
8” (20.3 cm) Round for
External Ventilation Duct*
*Must purchase 8” diameter to 10” diameter transition
locally. Transition should be installed past the duct cover.
**300 CFM ventilator kit for installation with 30” W. and 36” W. hoods only.
B
30” W.
28-3/8” (72.1 cm)
36” W.
34-3/8” (87.3 cm)
42” W.
40-3/8” (102.6 cm)
C
30” W.
14-13/16” (37.6 cm)
36” W.
17-13/16” (45.2 cm)
42” W.
20-13/16” (52.9 cm)
Clearance Dimensions
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
36”
(91.4 cm)
(Custom Hood)
(DBCV Wall Custom Ventilator System)
NOTE:
For best performance, it is recommended
that the bottom of the hood be 30” (76.2 cm) to
36” (91.4 cm) above the countertop. These dimensions
provide for safe and efficient operation of the hood.