Viking DTWN3648SS Installation Instructions - Page 9

Clearance Dimensions

Page 9 highlights

Dimensions & Specifications (DCIH Classic Chimney Island Hoods 36", 42", & 54") A (Duct cover width) 36"W. 12" (30.5 cm) 42"W. 12" (30.5 cm) 54"W. 18" (45.7 cm) (301.52"cm) A C (Duct height) 36"W. 42"W. 54"W. 16" (40.6 cm) or 28" (71.1 cm) or 40" (101.6 cm) (5.12"cm) C B (Hood width) 36"W. 35-7/8" (91.1 cm) B 42"W. 41-7/8" (106.4 cm) 54"W. 53-7/8" (136.8 cm) (763.20"cm) (351.64"cm) NOTE: Optional duct cover sold separately. DCIH Classic Chimney Island Hoods Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size 36" 42" 54" 12" (30.5 cm) 12" (30.5 cm) 18" (45.7 cm) 12" (30.5 cm) 16" (40.6 cm) or 28" (71.1 cm) or 40" (101.6 cm) 4 4 6 2 3 3 VINV600 VINV600 VINV1200* DEV900/1200* DEV900/1200*/1500** DEV1200*/1500** DIL900/1200 DIL900/1200 DIL1200 7" (17.8 cm) 7" (17.8 cm) 10" (25.4 cm) Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-Line-Maximum amps 4.7 7.4/3.9 4.7/6.6 10" (25.4 cm) 4.3 7.4/4.8/5.5 4.7/6.6 8.5 5.5/6.2 7.3 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods. 16 Clearance Dimensions (DCIH Classic Chimney Island Hoods) (913.46"cm) ((7611268672""t..mmo69 accinmmx..)) 33((796061""..t24mmoccaimmnx.)). NOTE: For best performance, it is recommended that the bottom of the hood be 30" (76.2 cm) to 36" (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Clearance Dimensions
17
Dimensions & Specifications
16
30”
(76.2 cm)
B
A
14”
(35.6 cm)
C
2”
(5.1 cm)
12”
(30.5 cm)
B (Hood width)
36”W.
35-7/8” (91.1 cm)
42”W.
41-7/8” (106.4 cm)
54”W.
53-7/8” (136.8 cm)
A (Duct cover width)
36”W.
12” (30.5 cm)
42”W.
12” (30.5 cm)
54”W.
18” (45.7 cm)
C (Duct height)
36”W.
42”W.
54”W.
16” (40.6 cm)
or
28” (71.1 cm)
or
40” (101.6 cm)
(DCIH Classic Chimney Island Hoods 36”, 42”, & 54”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct
run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE:
Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with
ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods.
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
36”
(91.4 cm)
NOTE:
Optional duct cover sold separately.
(DCIH Classic Chimney Island Hoods)
NOTE:
For best performance, it is recommended
that the bottom of the hood be 30” (76.2 cm) to
36” (91.4 cm) above the countertop. These dimensions
provide for safe and efficient operation of the hood.
DCIH Classic Chimney Island Hoods
Description
36”
42”
54”
Duct cover width
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
16” (40.6 cm) or 28” (71.1 cm) or 40” (101.6 cm)
Number of lights
4
4
6
Number of filters
2
3
3
Interior ventilator kits
VINV600
VINV600
VINV1200*
Exterior ventilator kits
DEV900/1200*
DEV900/1200*/1500**
DEV1200*/1500**
In-line ventilator kits
DIL900/1200
DIL900/1200
DIL1200
Interior duct size
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.7
4.3
8.5
Exterior—Maximum amps
7.4/3.9
7.4/4.8/5.5
5.5/6.2
In-Line—Maximum amps
4.7/6.6
4.7/6.6
7.3