Viking DTWN3648SS Installation Instructions - Page 15

DBCV Wall Custom Ventilator System

Page 15 highlights

Dimensions & Specifications (DBCV Wall Custom Ventilator System) A* *For best results, center the unit over B* the burners of the cooking product (front to back; right to left). Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted as shown on page 29. Bottom Cutout Dimensions Description 30" W. 36" W. 42" W. 48" W. Wall Hoods A (Hood Width) 28-11/16" (72.9 cm) 34-11/16" (88.1 cm) 40-11/16" (103.4 cm) 46-11/16" (118.6 cm) B (Hood Depth) 16-1/2" (41.9 cm) 16-1/2" (41.9 cm) 16-1/2" (41.9 cm) 16-1/2" (41.9 cm) DBCV Wall Custom Ventilator System Description Number of lights Number of filters Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size 30" 2 2 VINV300/600 DEV900/1200* DIL900/1200 7" (17.8 cm) 36" 2 2 VINV300/600 DEV900/1200* DIL900/1200 7" (17.8 cm) 42" 2 3 VINV600 DEV900/1200* DIL900/1200 7" (17.8 cm) 48" 3 3 VINV1200* DEV1200*/1500** DIL900/1200 10" (25.4 cm) Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-Line-Maximum amps 2.8/3.8 6.6/3.9 3.9/5.7 10" (25.4 cm) 2.8/3.8 3.8 6.6/3.9 6.6/3.9 3.9/5.7 3.9/5.7 6.8 4.3/5.1 6.1 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods. 28 Installing Hood Canopy (Custom Hood Canopy Cutouts) Custom Hood Canopy A B 1) Position ventilator system inside of the custom hood canopy and center it front to back and left to right. 2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided. Built-In Ventilator System 3) OPTIONAL Rear mounting holes fasten ventilator system to rear of custom hood canopy. 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

29
28
Dimensions & Specifications
(DBCV Wall Custom Ventilator System)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE:
Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods.
B*
A*
Bottom Cutout Dimensions
*For best results,
center the unit over
the burners of the
cooking product
(front to back; right
to left).
Make sure the back wall
of the custom hood
canopy is flush with the
cutout so the ventilator
system may be mounted
as shown on page 29.
Wall Hoods
Description
A (Hood Width)
B (Hood Depth)
30” W.
28-11/16” (72.9 cm)
16-1/2” (41.9 cm)
36” W.
34-11/16” (88.1 cm)
16-1/2” (41.9 cm)
42” W.
40-11/16” (103.4 cm)
16-1/2” (41.9 cm)
48” W.
46-11/16” (118.6 cm)
16-1/2” (41.9 cm)
A
B
Custom Hood
Canopy
1) Position ventilator
system inside of the
custom hood canopy
and center it front to
back and left to right.
2) Bottom mounting holes
fasten ventilator system
to bottom of custom
hood canopy with the
screws provided.
Built-In Ventilator
System
3) OPTIONAL
Rear mounting holes fasten
ventilator system to rear of
custom hood canopy.
Installing Hood Canopy
(Custom Hood Canopy Cutouts
)
DBCV Wall Custom Ventilator System
Description
30”
36”
42”
48”
Number of lights
2
2
2
3
Number of filters
2
2
3
3
Interior ventilator kits
VINV300/600
VINV300/600
VINV600
VINV1200*
Exterior ventilator kits
DEV900/1200*
DEV900/1200*
DEV900/1200*
DEV1200*/1500**
In-line ventilator kits
DIL900/1200
DIL900/1200
DIL900/1200
DIL900/1200
Interior duct size
7” (17.8 cm)
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
2.8/3.8
2.8/3.8
3.8
6.8
Exterior—Maximum amps
6.6/3.9
6.6/3.9
6.6/3.9
4.3/5.1
In-Line—Maximum amps
3.9/5.7
3.9/5.7
3.9/5.7
6.1