Yamaha DME32 DME32 V1.5 Supplement - Page 16

Editing Multiple Parameters Simultaneously, Improved Parameter Resolution, Support for Windows NT 4.

Page 16 highlights

16 Editing Multiple Parameters Simultaneously Previously, using DME Manager, only one parameter could be edited at a time. In Version 1.5, up to eight parameters of the same type can be selected and edited simultaneously. 1 While holding down the Shift key, click the parameters that you want to edit. The selected controls are highlighted by green boxes. 2 Release the Shift key when you've completed your selection. 3 Edit one of the selected parameters in the normal way. All the selected parameters are edited. Permanent links can be created between parameters by using the Link function. See the DME32 Owner's Manual for more information. Improved Parameter Resolution The resolution of frequency, gain, and level parameters has been improved, offering increased setting precision. PEQ and GEQ gain values, for examples, can now be set in 0.1 dB steps. Support for Windows NT 4.0, 2000 & Me In addition to the operating systems stated in the DME32 Owner's Manual, DME Manager V1.5 supports Windows NT 4.0, 2000, and Me. With Windows NT, USB cannot be used because it's not supported by that particular operating system. Software Version Mismatch Warning When DME Manager is started, it establishes communication with the DME32 and checks to see if its version number matches that of the DME32 system software. If it doesn't match, a warning message appears. You can still use the system even if this message appears, although, normal performance cannot be guaranteed and operation may be unreliable. For correct operation, the DME32 system software should be upgraded to match that of DME Manager. If the DME32 system software is a later version than DME Manager, no communications can be established during startup and the message "DME32 not found!" appears. DME32-Owner's Manual Supplement

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

16
DME32—Owner’s Manual Supplement
Editing Multiple Parameters Simultaneously
Previously, using DME Manager, only one parameter could be edited at a time. In Ver-
sion 1.5, up to eight parameters of the same type can be selected and edited simulta-
neously.
1
While holding down the Shift key, click the parameters that you want to edit.
The selected controls are highlighted by green boxes.
2
Release the Shift key when you’ve completed your selection.
3
Edit one of the selected parameters in the normal way.
All the selected parameters are edited.
Permanent links can be created between parameters by using the Link function.
See
the
DME32 Owner’s Manual
for more information.
Improved Parameter Resolution
The resolution of frequency, gain, and level parameters has been improved, offering
increased setting precision. PEQ and GEQ gain values, for examples, can now be set in
0.1 dB steps.
Support for Windows NT 4.0, 2000 & Me
In addition to the operating systems stated in the
DME32 Owner’s Manual,
DME Man-
ager V1.5 supports Windows NT 4.0, 2000, and Me. With Windows NT, USB cannot be
used because it’s not supported by that particular operating system.
Software Version Mismatch Warning
When DME Manager is started, it establishes communication with the DME32 and
checks to see if its version number matches that of the DME32 system software. If it
doesn’t match, a warning message appears. You can still use the system even if this mes-
sage appears, although, normal performance cannot be guaranteed and operation may
be unreliable. For correct operation, the DME32 system software should be upgraded
to match that of DME Manager.
If the DME32 system software is a later version than DME Manager, no communica-
tions can be established during startup and the message “DME32 not found!” appears.