Yamaha SY35 Owner's Manual (feature Reference) - Page 17

Details, Summary, Settings, Procedure - keys not working

Page 17 highlights

VOICE VECTOR Details: Step 1 is the first step recorded and step 50 is the last. Experience will give you a feel for relating specific points in a dynamic vector to the corresponding steps. l X-axis & Y-axis VV L.ED A B C D 1 X 0 Y 0 End Summary: These parameters define the position of the currently selected step on the X and Y axes of the level vector control range. Settings: -31 ... 0 ... +31 Procedure: After selecting the step to be recorded as described in the previous function, use the [4] and [6] cursor keys to place the underline cursor under the X or Y parameter. Use the [-1/NO] and [+1/YES] keys to set the value as required. Details: On the X (D-C) axis, a setting of -31 places the step as far as possible toward the D element while a setting of +31 places it as far as possible toward the C element. The Y (A-B) axis values work in the same way: a setting of -31 places the step as far as possible toward the B element while a setting of +31 places it as far as possible toward the A element. In both axes a setting of 0 places the step at center position. A +31 l Time VV L.ED A B C D 1 X 0 Y 0 End Summary: Multiplies the vector rate setting of the current level vector step only. Also allows vectors to be looped or ended at the current step. Settings: 1 ... 254, Rep, End Procedure: Use the [4] and [6] cursor keys to place the underline cursor under the rightmost value on the lower display line (Time). Use the [-1/NO] and [+1/YES] keys to select the required time value, repeat, or end. Details: Time values multiply the vector rate setting for the current step. If the vector rate parameter is set to 30ms, for example, setting the time parameter to 2 results in a step length of 60ms, setting it to 3 results in a step length of 90ms, and so on. Since the maximum time value is 254, extremely long steps can be created. If you select the "End" setting, the vector will end at the current step. The " R e p " setting causes the vector to loop back to the first step from the current step, repeating continuously. X axis D -31 0 C +31 -31 B Y axis 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83

VOICE VECTOR
12
Details:
Step 1 is the first step recorded and step 50
is the last. Experience will give you a feel for
relating specific points in a dynamic vector to
the corresponding steps.
X-axis & Y-axis
VV L.ED A
B
C
D
1X
0Y
0 End
Summary:
These parameters define the position of
the currently selected step on the X and Y axes
of the level vector control range.
Settings:
–31 … 0 … +31
Procedure:
After selecting the step to be recorded
as described in the previous function, use the [
4
]
and [
6
] cursor keys to place the underline
cursor under the X or Y parameter. Use the
[–1/NO] and [+1/YES] keys to set the value as
required.
Details:
On the X (D-C) axis, a setting of –31 places
the step as far as possible toward the D element
while a setting of +31 places it as far as possible
toward the C element. The Y (A-B) axis values
work
in
the
same
way:
a
setting
of
–31 places the step as far as possible toward the
B element while a setting of +31 places it as far
as possible toward the A element. In both axes a
setting of 0 places the step at center position.
C
A
B
D
+31
0
–31
+31
–31
X axis
Y axis
Time
VV L.ED A
B
C
D
1X
0Y
0 End
Summary:
Multiplies the vector rate setting of the
current level vector step only. Also allows vec-
tors to be looped or ended at the current step.
Settings:
1 … 254, Rep, End
Procedure:
Use the [
4
] and [
6
] cursor keys to place
the underline cursor under the rightmost value
on the lower display line (Time). Use the
[–1/NO] and [+1/YES] keys to select the re-
quired time value, repeat, or end.
Details:
Time values multiply the vector rate setting
for the current step. If the vector rate parameter
is set to 30ms, for example, setting the time
parameter to 2 results in a step length of 60ms,
setting it to 3 results in a step length of 90ms,
and so on. Since the maximum time value is
254, extremely long steps can be created.
If you select the “End” setting, the vector will
end at the current step.
The “Rep” setting causes the vector to loop
back to the first step from the current step, re-
peating continuously.