Disconnect power from the product.
View all Axis Communications M3026-VE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
AXIS M3026-VE Fixed Dome Network Camera System Options To reset the product to the factory default settings: 1. Disconnect power from the product. 2. Press and hold the control button and reconnect power. See Hardware Overview on page 6 . 3. Keep the control button pressed for about 15-30 seconds until the status LED indicator flashes amber. 4. Release the control button. The process is complete when the status LED indicator turns green. The product has been reset to the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.90 5. Use the tools provided on the Installation and Management Software CD to assign an IP address, set the password and access the video stream. This information is also available from the support pages on www.axis.com/techsup It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance. 52